ASTM-C697 2004
$58.50
C697-04 Standard Test Methods for Chemical, Mass Spectrometric, and Spectrochemical Analysis of Nuclear-Grade Plutonium Dioxide Powders and Pellets
Published By | Publication Date | Number of Pages |
ASTM | 2004 | 28 |
1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade plutonium dioxide powders and pellets to determine compliance with specifications.
1.2 The analytical procedures appear in the following order:
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Sections 6, 15, 24, 111, and 52.9 and 101.5.1.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents |
2 | Significance and Use Committee C-26 Safeguards Statement Reagents |
3 | Sample Handling Conditions Scope Summary of Test Method Apparatus FIG. 1 |
4 | Reagents Precautions Procedure Calculation Precision |
5 | Scope Summary of Test Method Interferences Apparatus Reagents and Materials Safety Precautions Sampling Preparation of Apparatus |
6 | Calibration Procedure Calculation Precision Scope Summary of Test Method Interferences (see and |
7 | Reagents FIG. 2 FIG. 3 |
8 | Pyrohydrolysis Procedure Measurement of Chloride and Fluoride |
9 | Precision Scope Summary of Test Method Interference Apparatus Reagents |
10 | Calibration Procedure FIG. 4 |
11 | Calculations Precision Scope Summary of Test Method Interferences Apparatus FIG. 5 |
12 | Reagents Procedure FIG. 6 |
13 | Calculation Precision Scope Summary of Test Method Apparatus TABLE 1 |
14 | Reagents and Materials Calibration Procedure Calculation Precision and Bias Scope |
15 | Summary of Test Methods Apparatus Reagents Procedure |
16 | Calculation Precision and Bias Scope TABLE 2 |
17 | Summary of Test Method Apparatus Reagents Operation Standardization Calculation Precision Scope |
18 | Summary of Test Method Interferences Apparatus Reagents Procedure FIG. 7 FIG. 8 |
19 | FIG. 9 |
20 | Calculation Precision and Bias Scope Summary of Test Method Apparatus |
21 | Reagents and Materials Procedure Photo Processing Photometry Calibration Calculation Precision and Bias Scope TABLE 3 |
22 | Summary of Test Method Interferences Apparatus Reagents Calibration of the Mass Spectrometer TABLE 4 |
23 | Procedure |
24 | Calculation |
25 | Precision and Bias Scope Summary of Test Method Interferences Apparatus Reagents |
26 | Safety Precautions Procedure FIG. 10 |
27 | Calculation Precision and Bias Keywords REFERENCES |