ASTM-D3558 2008
$44.96
D3558-08 Standard Test Methods for Cobalt in Water
Published By | Publication Date | Number of Pages |
ASTM | 2008 | 11 |
1.1 These test methods cover the determination of dissolved and total recoverable cobalt in water and wastewater by atomic absorption spectrophotometry. Three test methods are included as follows:
1.2 Test Method A has been used successfully with reagent water, potable water, river water, and wastewater. Test Method B has been used successfully with reagent water, potable water, river water, sea water and brine. Test Method C was successfully evaluated in reagent water, artificial seawater, river water, tap water, and a synthetic brine. It is the analyst’s responsibility to ensure the validity of these test methods for other matrices.
1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 11.7.1, 21.10, and 23.10.
7.1 This test method covers the determination of dissolved and total recoverable cobalt in most waters and waste waters. It is the user’s responsibility to ensure the validity of this test method in a particular matrix.
7.2 This test method is applicable in the range from 0.1 to 10 mg/L of cobalt. The range may be extended to concentrations greater than 10 mg/L by dilution of the sample.
17.1 This test method covers the determination of dissolved and total recoverable cobalt in most waters and brines. It is the user’s responsibility to ensure the validity of this test method in a particular matrix.
17.2 This test method is applicable in the range from 10 to 1000 ? g/L of cobalt. The range may be extended to concentrations greater than 1000 ? g/L by dilution of the samples.
27.1 This test method covers the determination of dissolved and total recoverable cobalt in most waters and wastewaters.
27.2 This test method is applicable in the range from 5 to 100 ? g/L of cobalt. The range can be increased or decreased by varying the volume of sample injected or the instrumental settings. High concentrations may be diluted but preferably should be analyzed by direct aspiration atomic absorption spectrophotometry.
27.3 This test method has been used successfully with reagent water, lake water, river water, well water, filtered tap water, condensate from a medium Btu coal gasification process, and effluent from a wood treatment plant. It is the user’s responsibility to ensure the validity of this test method for waters of untested matrices.
27.4 The analyst is encouraged to consult Practice D 3919 for a general discussion of interferences and sample analysis procedures for graphite furnace atomic absorption spectrophotometry.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | Scope Referenced Documents Terminology Significance and Use Purity of Reagents |
2 | Sampling Scope Summary of Test Method Interferences Apparatus Reagents and Materials |
3 | Standardization Procedure Calculation Precision and Bias FIG. 1 |
4 | Quality Control FIG. 2 TABLE 1 |
5 | Scope Summary of Test Method Interferences Apparatus Reagents and Materials |
6 | Standardization Procedure Calculation |
7 | Precision and Bias Quality Control FIG. 3 |
8 | FIG. 4 TABLE 2 |
9 | Scope Summary of Test Method Interferences Apparatus Reagents and Materials |
10 | Standardization Procedure Calculation Precision and Bias Quality Control TABLE 3 |
11 | Keywords |