AWWA C530-22 Pilot-Operated Control Valves

Published By Publication Date Number of Pages
AWWA 2022 44
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The purpose of this standard is to define the minimum requirements for pilot-operated control valves, including sizing considerations, design verification, testing, delivery, handling, and storage.

PDF Catalog

PDF Pages PDF Title
7 Foreword
I. Introduction.
I.A. Background. Pilot-operated control valves have been in use since the early 1900s in pipelines that carry liquids. Manufacturers of pilot-operated control valves have developed tight-closing rubber-seated and metal-seated products for pipeline use in
I.B. History. The need for a standard addressing pilot-operated control valves was recognized by the American Water Works Association (AWWA) in November 2001. A committee was appointed for the task of standardization; at the first inaugural meeting in Jun
I.C. Acceptance. In May 1985, the US Environmental Protection Agency (USEPA) entered into a cooperative agreement with a consortium led by NSF International (NSF) to develop voluntary third-party consensus standards and a certification program for direct
9 II. Special Issues. Conditions under which the pilot-operated control valve is to be operated must be evaluated carefully by the purchaser. This evaluation must include determination of the hydraulic characteristics of the system in which the valve will b
II.A. Chlorine and Chloramine Degradation of Elastomers. The selection of materials is critical for water service and distribution piping in locations where there is a possibility that elastomers will be in contact with chlorine or chloramines. Documented
III. Use of This Standard. It is the responsibility of the user of an AWWA standard to determine that the products described in that standard are suitable for use in the particular application being considered.
III.A. Purchaser Options and Alternatives. The following information should be provided by the purchaser.
11 III.B. Laying Length. Pilot-operated control valves do not have uniform laying lengths. Interchangeability between various manufacturers may not be possible without modification to the existing piping system. The purchaser is cautioned to obtain this info
III.C. Performance Test. This standard does not require the manufacturer to conduct the performance test on a fully assembled valve. Sec. 5.2 allows the manufacturer to conduct the tests separately on the main valve and the related pilots. If the purchase
III.D. Valve Test Media. The purchaser should review Sec. 5.2.1 of this standard and inform the supplier of the preferred valve test media. The standard allows factory testing of valves with air or water.
III.E. Modification to Standard. Any modification of the provisions, definitions, or terminology in this standard must be provided by the purchaser.
IV. Major Revisions. Major changes made to the standard in this revision include the following:
V. Comments. If you have any comments or questions about this standard, please call AWWA Engineering and Technical Services at 303.794.7711; write to the department at 6666 West Quincy Avenue, Denver, CO 80235-3098; or email at [email protected].
13 AWWA Standard
SECTION 1: GENERAL
Sec. 1.1 Scope
14 Sec. 1.2 Purpose
Sec. 1.3 Application
SECTION 2: REFERENCES
16 SECTION 3: DEFINITIONS
18 SECTION 4: REQUIREMENTS
Sec. 4.1 Data Provided by Manufacturer
Sec. 4.2 Materials
19 Sec. 4.3 General Design
23 Sec. 4.4 Workmanship and Painting
24 Sec. 4.5 Permeation
SECTION 5: VERIFICATION
Sec. 5.1 Inspection
Sec. 5.2 Testing
25 Sec. 5.3 Notice of Nonconformance
SECTION 6: DELIVERY
Sec. 6.1 Markings
26 Sec. 6.2 Shipping
Sec. 6.3 Affidavit of Compliance
SECTION 7: SIZING AND APPLICATION
Sec. 7.1 Valve Basics
28 Sec. 7.2 Control Functions
29 Sec. 7.3 Pressure-Reducing Function
31 Sec. 7.4 Pressure-Relief/Sustaining Function
33 Sec. 7.5 Solenoid Control Function
Sec. 7.6 Pump Control Function
36 Sec. 7.7 Altitude Control Function
37 Sec. 7.8 Rate-of-Flow Control Function
39 Appendix A
Installation, Operation, and Maintenance Pilot-Operated Control Valves
AWWA C530 2022