$158.93

Natural gas vehicles. Vehicle fuelling appliances

Published By Publication Date Number of Pages
BSI 2021 40
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. Weā€™re here to assist you 24/7.
Email:[email protected]

This document covers the design and manufacturing, installation and testing, operation and maintenance of vehicle fuelling appliances (VFA) for domestic fuelling of vehicles with compressed natural gas (CNG). This document is applicable to VFAs having the following technical limits: – maximum compressing capacity: 20 Nm3/h (NTP); – maximum internal storage volume for outdoor installation: 400 l; – maximum gas outlet pressure: 200 bar at 15 Ā°C; This document is applicable to VFAs supplied with natural gas as defined in local applicable gas composition regulations or EN 16723 2, or with other gases meeting these requirements including biomethane, upgraded coal-bed methane (CBM) and gas from liquefied natural gas (LNG) vaporizer (on-site or off-site). This document applies to VFAs not incorporating gas outlet metering systems.

PDF Catalog

PDF Pages PDF Title
2 undefined
9 1 Scope
2 Normative references
11 3 Terms and definitions
14 4 Abbreviations
5 Risk management
15 6 General principles of design
6.1 General construction
6.2 General requirements
16 6.3 Materials
6.4 Internal systems and components of VFA
6.4.1 Fuel delivery system
6.4.1.1 General
6.4.1.2 Fuelling hose
17 6.4.1.3 Fuelling nozzle
6.4.1.4 Breakaway device
18 6.4.2 Fuelling pressure discharge system
6.4.3 Locking system
6.4.4 Compressor
6.4.5 Gas containment system
6.4.5.1 General
6.4.5.2 Cylinders
19 6.4.6 Temperature compensation system
20 6.4.7 Dryer
6.4.8 Safety means
6.4.8.1 General
6.4.8.2 Overpressure safety devices
6.4.8.3 Overtemperature safety devices
6.4.8.4 Gas detection system
6.4.8.5 Minimum gas inlet pressure safety device
21 6.4.8.6 Emergency stop button
6.4.8.7 Fuelling hose rupture detection system
6.4.8.8 Protection of the inlet supply gas pipeline
6.4.8.9 Protection of the VFA from over current and over voltage
6.4.8.10 Earthing protection
6.4.9 Pipework
6.5 Permanent joining
6.6 Connection to the distribution gas network
22 6.7 Gas composition and odorization
6.8 Noise attenuation
6.9 Ventilation
7 Enclosure
23 8 Testing
8.1 General
8.2 Strength pressure (proof) test
8.2.1 General
8.2.2 Procedure of strength pressure (proof) test
24 8.2.3 Fatigue test
8.3 Leak testing
8.3.1 General
8.3.2 Procedure for gas leakage test
8.3.3 Liquid leakage testing
8.4 Checking of safety devices
25 8.5 Periodic inspection
8.5.1 General
8.5.2 Periodic inspection of cylinders
8.5.3 Periodic inspection of fuelling hose
9 Installation
9.1 General
9.2 VFA location
27 9.3 VFA installation outdoors
9.3.1 VFA location outdoors
9.3.2 Installation conditions
9.3.3 Ventilation conditions
9.4 VFA installation indoors
9.4.1 VFA location indoors
28 9.4.2 Installation conditions
9.4.3 Ventilation conditions
29 9.4.4 Compatibility with other gas appliances
9.5 Commissioning
10 Operation
10.1 General
10.2 Installation and servicing manual
10.2.1 General
30 10.2.2 Installation instructions
31 10.2.3 Maintenance instructions
32 10.2.4 Removal instructions for VFA
10.2.5 Servicing and inspection instructions
10.3 Userā€™s manual
10.3.1 General
10.3.2 Front cover
33 10.3.3 Safety section
10.3.4 Additional safety information
34 11 User of VFA
35 12 Marking and labelling
13 Maintenance and testing frequency of gas detection system
36 Annex A (informative)Additional safety precautions for indoor fuelling of NGV by means of VFA installed outdoors
37 Annex ZA (informative)Relationship between this European Standard and the Essential requirements of EU Directive 2014/68/EU (Pressure equipment Directive) aimed to be covered
BS EN 17278:2021