BS EN 50104:2019+A1:2023
$167.15
Electrical equipment for the detection and measurement of oxygen. Performance requirements and test methods
Published By | Publication Date | Number of Pages |
BSI | 2023 | 40 |
This document specifies general requirements for design, testing and performance, and describes the test methods that apply to portable, transportable and fixed equipment for the measurement of the oxygen concentration in gas mixtures indicating up to 25 % (v/v).
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | 1 Scope 2 Normative references |
8 | 3 Terms and definitions |
14 | 4 General requirements 4.1 Introduction 4.2 Design 4.2.1 General 4.2.2 Indicating devices 4.2.2.1 Indicators 4.2.2.2 Display and other devices for indication of measured values |
15 | 4.2.2.3 Suppression of indication and measured values below zero 4.2.2.4 Indicator light 4.2.3 Alarm signals 4.2.3.1 Alarm settings |
16 | 4.2.3.2 Alarm output functions 4.2.4 Fault signals 4.2.5 Adjustments |
17 | 4.2.6 Battery-powered equipment 4.2.7 Gas detection transmitter for use with separate gas detection control units 4.2.8 Separate gas detection control units for use with gas detection transmitter(s) 4.2.9 Equipment using software and/or digital technologies 4.3 Labelling and marking 4.4 Instruction manual |
20 | 5 Test methods 5.1 Introduction 5.2 General requirements for tests 5.2.1 Samples and sequence of tests 5.2.1.1 Test samples |
21 | 5.2.1.2 Sequence 5.2.1.3 Gas detection transmitters 5.2.1.4 Separate gas detection control units 5.2.2 Preparation of equipment before testing |
22 | 5.2.3 Mask for calibration and test 5.3 Normal conditions for test 5.3.1 General 5.3.2 Test gas(es) 5.3.3 Flow rate for test gases |
23 | 5.3.4 Power supply 5.3.5 Temperature 5.3.6 Pressure 5.3.7 Humidity 5.3.8 Acclimation time 5.3.9 Orientation 5.3.10 Communications options 5.3.11 Gas detection equipment as part of systems |
24 | 5.4 Test methods and performance requirements 5.4.1 General 5.4.2 Unpowered storage 5.4.2.1 Test 5.4.2.2 Initial preparation of the equipment |
25 | 5.4.3 Calibration curve and repeatability 5.4.3.1 Calibration curve 5.4.3.2 Repeatability 5.4.4 Stability 5.4.4.1 Battery-powered equipment 5.4.4.2 Fixed and transportable equipment 5.4.4.3 Portable equipment |
26 | 5.4.5 Alarm set-point(s) 5.4.5.1 General 5.4.5.2 Increasing oxygen concentration (equipment intended for measuring oxygen deficiency or enrichment) 5.4.5.3 Increasing oxygen concentration (equipment intended for measuring inertisation) 5.4.5.4 Decreasing oxygen concentration (equipment intended for measuring oxygen deficiency or enrichment) 5.4.6 Temperature |
27 | 5.4.7 Pressure 5.4.8 Humidity |
28 | 5.4.9 Air velocity 5.4.10 Flow rate 5.4.11 Orientation 5.4.11.1 Portable equipment and mobile sensors of fixed equipment |
29 | 5.4.11.2 Fixed and transportable equipment 5.4.12 Vibration 5.4.12.1 General 5.4.12.2 Test equipment 5.4.12.3 Procedures |
30 | 5.4.13 Drop test |
31 | 5.4.14 Warm-up time 5.4.15 Time of response 5.4.16 Battery capacity |
32 | 5.4.17 Power supply variations 5.4.18 Electromagnetic compatibility 5.4.19 Addition of sampling probe |
33 | 5.4.20 Poisons and other gases 5.4.20.1 General 5.4.20.2 Equipment with electrochemical sensors 5.4.20.3 Equipment with zirconium dioxide (ZrO2) sensors 5.4.21 Field calibration kit 5.4.22 Operation at or below the lower limit of the measuring range |
34 | 5.4.23 Verification of software and digital components |
35 | Annex A (informative)Significant changes between this edition and EN 50104:2010 |
38 | Annex ZZ (informative)Relationship between this European standard and the essential requirements of Directive 2014/34/EU aimed to be covered |