BS EN 50463-5:2012:2013 Edition
$142.49
Railway applications. Energy measurement on board trains – Conformity assessment
Published By | Publication Date | Number of Pages |
BSI | 2013 | 26 |
This European Standard specifies the conformity assessment arrangements for newly manufactured EMS installed on a traction unit. This includes the integration conformity assessment and installation conformity assessment. In addition, this document also specifies the conformity assessment procedures for device and ancillary component replacement (e.g. due to damage in service), and periodic check to verify the EMS conformity assessment remains valid.
This European Standard does not include elements related to conformity assessment aspects other than design review and testing provisions for the products, processes or services specified. Consequently, this part does not delete, change or interpret the general requirements for conformity assessment procedures and vocabulary detailed in EN/ISO/IEC 17000.
This European Standard does not cover the conformity assessment schemes that, according to CENELEC Internal Regulations, are the responsibility of ISO policy committee “Committee on conformity assessment” (ISO/CASCO).
PDF Catalog
PDF Pages | PDF Title |
---|---|
9 | 1 Scope 2 Normative references 3 Terms, definitions and abbreviations 3.1 Terms and definitions 3.1.1 conformity assessment 3.1.2 Conformity Assessment File CAF 3.1.3 EMS installation 3.1.4 EMS integration |
10 | 3.1.5 Implementation Under Assessment IUA 3.1.6 installer 3.1.7 integrator 3.1.8 periodic re-verification 3.1.9 protective interface 3.1.10 traction unit type 3.2 Abbreviations |
11 | 4 Conformity assessment approach 4.1 General 4.2 Situation of applicability 4.3 General Methodology |
12 | 4.4 EMS Specific Methodology |
13 | 4.4.1 EMS integration design review 4.4.2 EMS integration type test 4.4.3 EMS installation design review 4.4.4 EMS installation type test 4.4.5 EMS installation routine test 4.4.6 EMS periodic re-verification 4.4.7 Replacement of devices and ancillary components 5 Conformity assessment procedures 5.1 General 5.2 EMS integration design review 5.2.1 EMS integration design review documentation |
14 | 5.2.2 EMS integration design review assessment 5.2.3 Integration Design Review Report (IDRR) 5.3 EMS integration type test 5.3.1 Integration type test procedure |
15 | 5.3.2 Integration type tests 5.3.2.1 Visual inspection 5.3.2.2 Power-up 5.3.2.3 Power-down 5.3.2.4 Traction supply system change 5.3.2.5 EMS Data flow test 5.3.3 Integration Type Test Report (ITTR) |
16 | 5.4 EMS installation design review 5.4.1 EMS installation design review documentation 5.4.2 EMS installation design review assessment 5.4.2.1 Insulation 5.4.2.2 Enclosure |
17 | 5.4.2.3 Protection from non-authorised access 5.4.2.4 General safety requirements 5.4.3 Installation Design Review Report (SDRR) 5.5 EMS Installation type test 5.5.1 Installation procedure 5.5.2 Installation type test procedure 5.5.3 Installation type tests 5.5.3.1 Visual inspection |
18 | 5.5.3.2 EMS data flow test 5.5.3.3 Data transfer through all communication channels 5.5.4 Installation Type Test Report (STTR) 5.6 EMS installation routine test |
19 | 5.6.1 Installation routine test procedure 5.6.2 Routine tests 5.6.2.1 Visual inspection 5.6.2.2 Power-up 5.6.2.3 Power-down 5.6.2.4 Traction supply system change |
20 | 5.6.2.5 Insulation 5.6.2.6 Protection from non-authorised access 5.6.2.7 Indicator 5.6.2.8 General safety requirements 5.6.2.9 EMS data flow test 5.6.3 Installation Routine Test Report (IRTR) 5.7 Periodic re-verification 5.7.1 Procedure |
21 | 5.7.2 Re-verification Report (RVR) 5.8 Replacement of devices and ancillary components 5.8.1 General |
22 | 5.8.2 Documentation 5.8.3 Item replacement conformity assessment 5.8.4 Software 5.8.5 Programmable parameters 5.8.6 Replacement report |