BS EN IEC 61857-32:2019

$142.49

Electrical insulation systems. Procedures for thermal evaluation – Multifactor evaluation with increased factors during diagnostic testing

Published By Publication Date Number of Pages
BSI 2019 24
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of the 61857 series is focused on applications where other possible factors need to be incorporated to evaluate any influence on the performance of the electrical insulation system (EIS). Multi-factor evaluation is the most complex type of project to design and conduct. Clear guidelines are needed to give the user of this document a uniform approach and a method to analyse the test results.

This document is for applications where the stresses are some combination of other factors of influence identified in IEC 60505 . The multi-factor stresses are applied during the diagnostic portion of each test cycle.

A few examples of other factors of influence or multi-factor stresses are:

  • high vibration;

  • submersion in oils, water, or solutions;

  • voltage higher than the test voltage of the reference EIS;

  • decreased cold shock temperature.

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
7 English
CONTENTS
8 FOREWORD
10 INTRODUCTION
11 1 Scope
2 Normative references
3 Terms and definitions
12 4 Procedure
5 Test objects
6 EIS evaluation
Figures
Figure 1 – Overview
13 7 Part 1: Baseline structure
7.1 General
7.2 Illustration of the structure – Thermal evaluation
14 7.3 Example of thermal evaluation of a candidate EIS
Figure 2 – Illustration of the establishment of the thermal classificationof the candidate EIS
Tables
Table 1 – Example of a reference EIS and candidate EIS; performanceat temperature and thermal classification
15 8 Part 2: Evaluation of other factors
8.1 General
8.2 Selection of the ageing temperature for the one-temperature comparison
Table 2 – Example of ageing temperature selection forthe one-temperature comparison
16 8.3 Application of increased or additional diagnostic factors
9 Analysis of data
9.1 General
9.2 Evaluation of the other factors of influence
9.3 Comparison of the results is between the baseline EIS and any of the sets of results for other factors of influence
17 10 Report
18 Bibliography
19 Annex A (informative) Example of a test data sheet report
Table A.1 – Example of a test data sheet
20 Annex B (informative)Example of thermal ageing data for the reference EIS – Establishing the correlation time
Figure B.1 – Reference data with the known temperature of 186 °C,time coordinate established at 45 200 h
21 Annex C (informative)Example of a test data sheet for a baseline candidatethermal classification
Table C.1 – Example of a test data sheet for a baseline candidate
22 Annex D (informative)Establishing the thermal endurance of the baseline candidateusing the reference correlation time
Figure D.1 – Baseline candidate data with the known thermal index of 161 °Cwhen the time coordinate from the reference is 45 200 hours
BS EN IEC 61857-32:2019