IEEE C37.104 2012
$50.38
IEEE Guide for Automatic Reclosing of Circuit Breakers for AC Distribution and Transmission Lines
Published By | Publication Date | Number of Pages |
IEEE | 2012 | 72 |
Revision Standard – Active. Current reclosing practices for transmission and distribution lines are described. Application considerations and coordination practices of reclosing are also discussed. (An errata is available at http://standards.ieee.org/findstds/errata/C37.104-2012_errata.pdf)
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std C37.104-2012 Front Cover |
2 | Blank Page |
3 | Title Page |
6 | Notice to users Laws and regulations Copyrights Updating of IEEE documents Errata Patents |
8 | Participants |
10 | Introduction |
11 | Contents Important Notice |
12 | 1. Overview 1.1 Scope 1.2 Purpose |
13 | 2. Normative references 3. Definitions |
14 | 4. Fundamentals and applications |
15 | 4.1 The autoreclosing function performed by a reclosing relay |
16 | 4.2 Autoreclosing nomenclature |
17 | 4.3 Autoreclosing circuitry and logic |
18 | 4.3.1 Understanding selective autoreclosing logic |
19 | 4.3.2 Understanding of device internal logic and processing |
20 | 4.4 Autoreclosing settings 4.4.1 Number of reclosing attempts 4.4.2 Dead time 4.4.3 Autoreclosing reset time and autoreclosing lockout |
21 | 4.5 Autoreclosing supervision |
22 | 4.5.1 Voltage supervision of autoreclosing |
23 | 4.6 Autoreclose blocking |
24 | 4.7 Application considerations 4.7.1 Lines with underground cables |
25 | 4.7.2 Autoreclosing following bus faults |
26 | 4.7.3 Circuit breakers 4.7.4 Effects of autoreclosing on disk type overcurrent relays (ratcheting or notching) |
27 | 4.7.5 Radical circuits 4.7.6 Lines with automatic sectionalizing |
28 | 4.7.7 Adaptive autoreclosing |
29 | 4.7.8 Reclosing and motor loads 4.7.9 Wind turbines |
30 | 4.8 Substation controller 4.9 SCADA 5. Autoreclosing for distribution systems 5.1 Distribution system overview |
31 | 5.2 Distribution autoreclosing practices 5.2.1 Number of autoreclose attempts 5.2.2 Coordination concerns |
32 | 5.2.3 Autoreclosing for distribution bus faults 5.3 Autoreclosing coordination practices 5.3.1 Circuit reclosers 5.3.2 Sectionalizers |
33 | 5.3.3 Fuse saving and fuse blowing schemes 5.3.3.1 Fuse saving schemes |
34 | 5.3.3.2 Fuse blowing schemes 5.3.4 Sequence coordination |
36 | 5.3.5 Autoreclose blocking 5.4 Application considerations 5.4.1 Dispersed generation and other sources |
37 | 5.4.2 Capacitors 5.4.3 Transformer load tap changers 6. Autoreclosing for transmission systems 6.1 Transmission systems overview |
38 | 6.2 Autoreclosing methods 6.2.1 High-speed autoreclosing |
39 | 6.2.1.1 Stability considerations |
41 | 6.3 Application considerations 6.3.1 Blocking of autoreclosing 6.3.2 Turbine-generator considerations |
43 | 6.3.3 Other system elements 6.3.4 Multiple-breaker line terminations |
44 | 6.3.5 Special considerations for series compensated lines 6.3.6 Guidelines for setting synchronism-check angles |
46 | 6.3.7 Leader-follower autoreclosing of transmission lines |
48 | 6.3.7.1 Weak source/strong source considerations |
49 | 6.3.8 Transformer considerations 6.3.8.1 Transformers in-series with transmission line 6.3.8.2 Transformers tapped on a transmission line |
51 | 6.3.9 Multiple-terminal lines |
52 | 6.3.10 Gas-insulated bus 6.3.11 Transmission line reclosing and interfacing with automatic sectionalizing schemes |
55 | 7. New technologies/special applications 7.1 Ethernet based applications to autoreclosing |
56 | 7.2 Coordination of fast valving and high-speed reclosing |
57 | 7.3 Sychrophasor applications 7.3.1 Fault location to supervise reclosing on mixed lines 7.4 Autoreclosing (load restoration) after underfrequency load shedding |
58 | 7.5 Point-on-wave (POW) and staggered pole autoreclosing 7.6 Multi-Phase Autoreclosing (MPAR) |
60 | 7.7 Pulseclosing 7.7.1 Pulsefinding |
61 | Annex A (informative) Bibliography |
67 | Annex B (informative) History of automatic reclosing |
69 | Annex C (informative) Sample method to indicate autoreclosing mode and timing |
72 | Annex D (informative) Index |