{"id":149006,"date":"2024-10-19T08:46:32","date_gmt":"2024-10-19T08:46:32","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-c1399-c1399m\/"},"modified":"2024-10-25T01:01:35","modified_gmt":"2024-10-25T01:01:35","slug":"astm-c1399-c1399m","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-c1399-c1399m\/","title":{"rendered":"ASTM-C1399\/C1399M"},"content":{"rendered":"

ASTM C1399\/C1399M-10-Reapproved2015<\/h3>\n

Withdrawn Standard: Standard Test Method for Obtaining Average Residual-Strength of Fiber-Reinforced Concrete (Withdrawn 2024)<\/h4>\n
\n

ASTM C1399\/C1399M<\/h4>\n

Scope<\/strong><\/p>\n

\n

1.1<\/span> This test method covers the determination of residual strength of a fiber\u2013reinforced concrete test beam. The average residual strength is computed using specified beam deflections that are obtained from a beam that has been cracked in a standard manner. The test provides data needed to obtain that portion of the load\u2013deflection curve beyond which a significant amount of cracking damage has occurred and it provides a measure of post\u2013cracking strength, as such strength is affected by the use of fiber\u2013reinforcement.<\/p>\n<\/p><\/div>\n

\n

1.2<\/span> The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.<\/p>\n<\/p><\/div>\n

\n

1.3<\/span> This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i><\/p>\n<\/p><\/div>\n

Keywords<\/strong><\/p>\n

fiber\u2013reinforced concrete; residual strength; flexure testing; post cracking strength;<\/p>\n

ICS Code<\/strong><\/p>\n

ICS Number Code 91.100.30 (Concrete and concrete products)<\/p>\n

DOI:<\/strong> 10.1520\/C1399_C1399M-10R15<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"

C1399\/C1399M-10(2015) Standard Test Method for Obtaining Average Residual-Strength of Fiber-Reinforced Concrete<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2015<\/td>\n6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":149009,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1258,2637],"product_tag":[],"class_list":{"0":"post-149006","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-100-30","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/149006","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/149009"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=149006"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=149006"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=149006"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}