{"id":202557,"date":"2024-10-19T12:57:26","date_gmt":"2024-10-19T12:57:26","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ca-energycode-2019-2\/"},"modified":"2024-10-25T05:35:12","modified_gmt":"2024-10-25T05:35:12","slug":"ca-energycode-2019-2","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ca\/ca-energycode-2019-2\/","title":{"rendered":"CA EnergyCode 2019"},"content":{"rendered":"

The California Energy Code (CEC) contains energy conservation standards applicable to most residential and nonresidential buildings throughout California, including schools.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nCover <\/td>\n<\/tr>\n
3<\/td>\nCopyright <\/td>\n<\/tr>\n
4<\/td>\nPREFACE
ACKNOWLEDGEMENTS <\/td>\n<\/tr>\n
6<\/td>\nCalifornia Agency Information Contact List <\/td>\n<\/tr>\n
7<\/td>\nHOW TO DETERMINE WHERECHANGES HAVE BEEN MADE <\/td>\n<\/tr>\n
8<\/td>\nTABLE OF CONTENTS <\/td>\n<\/tr>\n
10<\/td>\nSUBCHAPTER 1 ALL OCCUPANCIES\u2014
\n GENERAL PROVISIONS
Section
\n 100.0 Scope <\/td>\n<\/tr>\n
12<\/td>\n100.1 Definitions and Rules of Construction <\/td>\n<\/tr>\n
39<\/td>\n100.2 Calculation of Time Dependent
\n Valuation (TDV) Energy <\/td>\n<\/tr>\n
42<\/td>\nSUBCHAPTER 2 ALL OCCUPANCIES\u2014
\n MANDATORY REQUIREMENTS FOR THE
\n MANUFACTURE, CONSTRUCTION AND
\n INSTALLATION OF SYSTEMS, EQUIPMENT
\n AND BUILDING COMPONENTS
Section
\n 110.0 Systems and Equipment\u2014General
110.1 Mandatory Requirements for Appliances <\/td>\n<\/tr>\n
43<\/td>\n110.2 Mandatory Requirements for Space-
\n Conditioning Equipment <\/td>\n<\/tr>\n
52<\/td>\n110.3 Mandatory Requirements for Service
\n Water-Heating Systems and Equipment <\/td>\n<\/tr>\n
53<\/td>\n110.4 Mandatory Requirements for Pool and
\n Spa Systems and Equipment <\/td>\n<\/tr>\n
54<\/td>\n110.5 Natural Gas Central Furnaces, Cooking
\n Equipment, Pool and Spa Heaters and Fireplaces:
\n Pilot Lights Prohibited
110.6 Mandatory Requirements for
\n Fenestration Products and Exterior Doors <\/td>\n<\/tr>\n
56<\/td>\n110.7 Mandatory Requirements to Limit
\n Air Leakage
110.8 Mandatory Requirements for Insulation,
\n Roofing Products and Radiant Barriers <\/td>\n<\/tr>\n
58<\/td>\n110.9 Mandatory Requirements for Lighting
\n Control <\/td>\n<\/tr>\n
60<\/td>\n110.10 Mandatory Requirements
\n for Solar Ready Buildings <\/td>\n<\/tr>\n
62<\/td>\n110.11 Mandatory Requirements for
\n Electrical Power Distribution System <\/td>\n<\/tr>\n
63<\/td>\n110.12 Mandatory Requirements for
\n Demand Management <\/td>\n<\/tr>\n
66<\/td>\nSUBCHAPTER 3 NONRESIDENTIAL, HIGH-RISE
\n RESIDENTIAL HOTEL\/MOTEL OCCUPANCIES,
\n AND COVERED PROCESSES\u2014MANDATORY
\n REQUIREMENTS
Section
\n 120.0 General
120.1 Requirements for Ventilation and
\n Indoor Air Quality <\/td>\n<\/tr>\n
76<\/td>\n120.2 Required Controls for Space-
\n Conditioning Systems <\/td>\n<\/tr>\n
79<\/td>\n120.3 Requirements for Pipe Insulation <\/td>\n<\/tr>\n
80<\/td>\n120.4 Requirements for Air Distribution
\n System Ducts and Plenums <\/td>\n<\/tr>\n
82<\/td>\n120.5 Required Nonresidential
\n Mechanical System Acceptance
120.6 Mandatory Requirements
\n for Covered Processes <\/td>\n<\/tr>\n
88<\/td>\n120.7 Mandatory Insulation Requirements <\/td>\n<\/tr>\n
89<\/td>\n120.8 Nonresidential Building Commissioning <\/td>\n<\/tr>\n
91<\/td>\n120.9 Mandatory Requirements
\n for Commercial Boilers <\/td>\n<\/tr>\n
92<\/td>\nSUBCHAPTER 4 NONRESIDENTIAL,
\n HIGH-RISE RESIDENTIAL AND HOTEL\/
\n MOTEL OCCUPANCIES\u2014MANDATORY
\n REQUIREMENTS FOR LIGHTING SYSTEMS
\n AND EQUIPMENT, AND ELECTRICAL
\n POWER DISTRIBUTION SYSTEMS
Section
\n 130.0 Lighting Systems and Equipment,
\n and Electrical Power Distribution
\n Systems\u2014General <\/td>\n<\/tr>\n
93<\/td>\n130.1 Mandatory Indoor Lighting Controls <\/td>\n<\/tr>\n
97<\/td>\n130.2 Outdoor Lighting Controls and Equipment <\/td>\n<\/tr>\n
99<\/td>\n130.3 Sign Lighting Controls
130.4 Lighting Control Acceptance and
\n Installation Certificate Requirements <\/td>\n<\/tr>\n
100<\/td>\n130.5 Electrical Power Distribution Systems <\/td>\n<\/tr>\n
102<\/td>\nSUBCHAPTER 5 NONRESIDENTIAL,
\n HIGH-RISE RESIDENTIAL AND HOTEL\/
\n MOTEL OCCUPANCIES\u2014PERFORMANCE
\n AND PRESCRIPTIVE COMPLIANCE
\n APPROACHES FOR ACHIEVING ENERGY
\n EFFICIENCY
Section
\n 140.0 Performance and Prescriptive
\n Compliance Approaches
140.1 Performance Approach: Energy Budgets
140.2 Prescriptive Approach
140.3 Prescriptive Requirements
\n for Building Envelopes <\/td>\n<\/tr>\n
110<\/td>\n140.4 Prescriptive Requirements for
\n Space-Conditioning Systems <\/td>\n<\/tr>\n
118<\/td>\n140.5 Prescriptive Requirements for
\n Service Water-Heating Systems
140.6 Prescriptive Requirements
\n for Indoor Lighting <\/td>\n<\/tr>\n
131<\/td>\n140.7 Prescriptive Requirements for
\n Outdoor Lighting <\/td>\n<\/tr>\n
134<\/td>\n140.8 Prescriptive Requirements for Signs
140.9 Prescriptive Requirements
\n for Covered Processes <\/td>\n<\/tr>\n
140<\/td>\nSUBCHAPTER 6 NONRESIDENTIAL,
\n HIGH-RISE RESIDENTIAL AND HOTEL\/
\n MOTEL OCCUPANCIES\u2014ADDITIONS,
\n ALTERATIONS AND REPAIRS
Section
\n 141.0 Additions, Alterations and Repairs
\n to Existing Nonresidential, High-Rise
\n Residential, and Hotel\/Motel Buildings,
\n to Existing Outdoor Lighting, and to
\n Internally and Externally Illuminated Signs <\/td>\n<\/tr>\n
147<\/td>\n141.1 Requirements for Covered Processes
\n in Additions, Alterations to Existing
\n Nonresidential, High-Rise Residential,
\n and Hotel\/Motel Buildings <\/td>\n<\/tr>\n
148<\/td>\nSUBCHAPTER 7 LOW-RISE RESIDENTIAL
\n BUILDINGS\u2014MANDATORY FEATURES
\n AND DEVICES
Section
\n 150.0 Mandatory Features and Devices <\/td>\n<\/tr>\n
162<\/td>\nSUBCHAPTER 8 LOW-RISE RESIDENTIAL
\n BUILDINGS\u2014PERFORMANCE AND
\n PRESCRIPTIVE COMPLIANCE
\n APPROACHES
Section
\n 150.1 Performance and Prescriptive Compliance
\n Approaches for Low-Rise
\n Residential Buildings <\/td>\n<\/tr>\n
174<\/td>\nSUBCHAPTER 9 LOW-RISE RESIDENTIAL
\n BUILDINGS\u2014ADDITIONS AND
\n ALTERATIONS TO EXISTING LOW-RISE
\n RESIDENTIAL BUILDINGS
Section
\n 150.2 Energy Efficiency Standards for Additions
\n and Alterations to Existing Low-Rise
\n Residential Buildings <\/td>\n<\/tr>\n
184<\/td>\nAPPENDIX 1\u2013A STANDARDS AND DOCUMENTS
\n REFERENCED IN THE ENERGY EFFICIENCY
\n REGULATIONS <\/td>\n<\/tr>\n
190<\/td>\nAPPENDIX 1-B ENERGY COMMISSION
\n DOCUMENTS INCORPORATED BY REFERENCE
\n IN THEIR ENTIRETY <\/td>\n<\/tr>\n
192<\/td>\nHISTORY NOTE APPENDIX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

California Energy Code, Title 24, Part 6 (W\/ ERRATA)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
CA<\/b><\/a><\/td>\n2019<\/td>\n195<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":202558,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2720],"product_tag":[],"class_list":{"0":"post-202557","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ca","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/202557","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/202558"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=202557"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=202557"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=202557"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}