{"id":222111,"date":"2024-10-19T14:25:03","date_gmt":"2024-10-19T14:25:03","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-137912012\/"},"modified":"2024-10-25T08:00:03","modified_gmt":"2024-10-25T08:00:03","slug":"bs-en-iso-137912012","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-137912012\/","title":{"rendered":"BS EN ISO 13791:2012"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
11<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3 Terms, definitions, symbols and units 3.1 Terms and definitions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 3.2 Symbols and units <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 3.3 Subscripts <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 4 Determination of internal temperatures 4.1 Assumptions 4.2 Evaluation of the relevant temperatures 4.2.1 Internal air temperature <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 4.2.2 Internal surface temperature <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 4.2.3 Surface delimiting two solid layers 4.2.4 Surface of an air layer <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 4.2.5 External surface of a room element 4.2.6 Relevant temperatures for special construction elements 4.2.6.1 Ceiling below an attic <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 4.2.6.2 Floor on ground 4.2.6.3 Floor over cellar 4.2.6.4 Floor over crawl space 4.2.6.5 Glazed element 4.3 Room thermal balance <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 4.4 Boundary conditions 4.4.1 Single room 4.4.2 Similar rooms 4.4.2.1 Partition (vertical) wall <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 4.4.2.2 Ceiling\/floor <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 4.4.3 Adjacent room with defined value of the air temperature <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 4.4.4 Floor on ground 4.4.5 Cellar or crawl space 4.4.6 Ceiling below attic 4.5 Terms in the thermal balance equations 4.5.1 Heat conduction through components <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 4.5.2 Convective heat transfer 4.5.2.1 General 4.5.2.2 Convective heat flow rate\uf020at the surfaces of an element <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | 4.5.2.3 Convective heat transfer through unventilated air layers <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 4.5.2.4 Convective heat transfer through ventilated air layer <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 4.5.3 Short-wave radiation heat transfers 4.5.3.1 Short-wave radiation heat transfer at the external surface of opaque element <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | 4.5.3.2 Short-wave radiation heat transfer at the internal surface of opaque elements <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | 4.5.3.3 Short-wave radiation heat flow rate for transparent elements (including blinds and curtains) <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 4.5.3.4 Solar to air heat flow rate 4.5.3.5 Sunlit area of room element 4.5.4 Long-wave radiation heat transfer 4.5.4.1 Heat flow rate at the external surface <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | 4.5.4.2 Heat flow rate at the internal surface <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 4.5.4.3 Air layers 4.5.5 Internal gains <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 4.5.6 Heat flow due to ventilation 4.5.6.1 General 4.5.6.2 Natural ventilation 4.5.6.3 Mechanical ventilation <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 5 Determination of internal humidity 6 Procedure for carrying out calculations 6.1 General 6.2 Design climatic data 6.2.1 General <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 6.2.2 Long-period design climatic data 6.2.3 Design warm sequence 6.3 Geometrical and thermophysical characteristics of room elements 6.4 Design internal gains 6.5 Design occupant behaviour <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | 6.6 Calculation procedure 6.6.1 General 6.6.2 Definition of the starting conditions 6.6.3 Prediction of the internal temperatures 7 Report of the calculation <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | 8 Validation procedures 8.1 Introduction 8.2 Validation of heat transfer processes 8.2.1 General 8.2.2 Heat conduction through opaque elements <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | 8.2.3 Internal long-wave radiation exchanges <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | 8.2.4 Sunlit area of a window due to external obstructions <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | 8.3 Validation procedure for the whole calculation method 8.3.1 General <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | 8.3.2 Geometry for the test rooms <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | 8.3.3 Thermophysical properties of opaque walls 8.3.4 Properties of glazing <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | 8.3.5 Solar parameters <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | 8.3.6 Boundary conditions <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | 8.3.7 Internal energy sources <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | 8.3.8 Ventilation 8.3.9 Descriptions of the validation tests 8.3.9.1 General <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | 8.3.9.2 Results of validations <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Thermal performance of buildings. Calculation of internal temperatures of a room in summer without mechanical cooling. General criteria and validation procedures<\/b><\/p>\n |