{"id":242362,"date":"2024-10-19T15:53:10","date_gmt":"2024-10-19T15:53:10","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-16-30342028-dc\/"},"modified":"2024-10-25T10:45:27","modified_gmt":"2024-10-25T10:45:27","slug":"bsi-16-30342028-dc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-16-30342028-dc\/","title":{"rendered":"BSI 16\/30342028 DC"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3 Terms and definitions 4 Test conditions 4.1 Test environment <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 5 Test apparatus 5.1 Test equipment <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.2 Test wall and mounting <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.3 Source of heat 5.3.1 Burner <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.3.2 Flow meters and flow rates <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.3.3 Verification <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 5.4 Shock producing device 5.5 Positioning of source of heat 5.6 Continuity checking arrangements for electric power and control cables with rated voltage up to and including 600\/1 000 V 1.7 Fuses <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6 Test specimen (Electric power and control cables with rated voltage up to and including 600\/1 000 V) 6.1 Test specimen preparation 6.2 Test specimen mounting <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 7 Test procedure (Electric power and control cables with rated voltage up to and including 600\/1 000 V) 7.1 Test equipment and arrangement 7.2 Electrical connections <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 7.3 Flame and shock application 7.4 Electrification 8 Performance requirements (Electric power and control cables with rated voltage up to and including 600\/1 000 V) 7.5 Flame application time 7.6 Acceptance criteria 8 Retest procedure 9 Test report (Electric power and control cables with rated voltage up to and including 600\/1 000 V) <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 10 Cable marking <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Annex A (normative) Verification procedure for the source of heat A.1 Measuring equipment A.2 Procedure <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | A.3 Evaluation A.4 Further verification A.5 Verification report\u2003 <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Annex B (informative) Guidance on the choice of recommended test apparatus B.1 Burner and Venturi B.2 Test wall material B.3 Influence of draughts in the test chamber B.4 Guidance on provision of a suitable test chamber <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" BS EN 60331-2. Tests for electric cables under fire conditions. Circuit integrity. Part 2. Test method for fire with shock at a temperature of at least 830\u00b0C for cables of rated voltage up to and including 0,6\/1,0 kV and with an overall diameter not exceeding 20mm<\/b><\/p>\n |