{"id":245842,"date":"2024-10-19T16:10:19","date_gmt":"2024-10-19T16:10:19","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-1185-2019\/"},"modified":"2024-10-25T11:11:12","modified_gmt":"2024-10-25T11:11:12","slug":"ieee-1185-2019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-1185-2019\/","title":{"rendered":"IEEE 1185 2019"},"content":{"rendered":"

Revision Standard – Active. Guidance for the proper installation of cable in generating stations and industrial facilities is provided in this recommended practice.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std 1185\u2122-2019 Front cover <\/td>\n<\/tr>\n
2<\/td>\nTitle page <\/td>\n<\/tr>\n
4<\/td>\nImportant Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n
7<\/td>\nParticipants <\/td>\n<\/tr>\n
9<\/td>\nIntroduction <\/td>\n<\/tr>\n
11<\/td>\nContents <\/td>\n<\/tr>\n
13<\/td>\nList of Figures <\/td>\n<\/tr>\n
14<\/td>\nList of Tables <\/td>\n<\/tr>\n
15<\/td>\n1.\u2002Overview
1.1\u2002Scope
1.2\u2002Purpose
1.3\u2002Units of measure <\/td>\n<\/tr>\n
16<\/td>\n1.4\u2002Word usage
2.\u2002Normative references <\/td>\n<\/tr>\n
17<\/td>\n3.\u2002Definitions, acronyms, and abbreviations
3.1\u2002Definitions
3.2\u2002Acronyms and abbreviations <\/td>\n<\/tr>\n
18<\/td>\n4.\u2002Planning the pull
4.1\u2002Cable storage, handling, and re-reeling <\/td>\n<\/tr>\n
22<\/td>\n4.2\u2002Cable cold temperature limits <\/td>\n<\/tr>\n
23<\/td>\n4.3\u2002Raceway types and fill recommendations <\/td>\n<\/tr>\n
26<\/td>\n4.4\u2002Planning activities <\/td>\n<\/tr>\n
27<\/td>\n4.5\u2002Pre-installation activities for duct banks <\/td>\n<\/tr>\n
31<\/td>\n4.6\u2002Distance limitations
4.7\u2002Reel position and reel back tension <\/td>\n<\/tr>\n
32<\/td>\n4.8\u2002Bend location <\/td>\n<\/tr>\n
33<\/td>\n4.9\u2002Minimum bend radius <\/td>\n<\/tr>\n
36<\/td>\n4.10\u2002Maximum allowable pulling tension (MAPT) <\/td>\n<\/tr>\n
39<\/td>\n4.11\u2002Expected pulling tension <\/td>\n<\/tr>\n
41<\/td>\n4.12\u2002Cable configurations and cable jamming <\/td>\n<\/tr>\n
42<\/td>\n4.13\u2002Weight correction factor <\/td>\n<\/tr>\n
44<\/td>\n4.14\u2002Maximum allowable sidewall pressure <\/td>\n<\/tr>\n
45<\/td>\n4.15\u2002Expected SWBP
5.\u2002Accessories required for the pull
5.1\u2002Rope and tapes <\/td>\n<\/tr>\n
48<\/td>\n5.2\u2002Swivels and sheaves <\/td>\n<\/tr>\n
50<\/td>\n5.3\u2002Rollers <\/td>\n<\/tr>\n
51<\/td>\n5.4\u2002Pulling eyes <\/td>\n<\/tr>\n
52<\/td>\n5.5\u2002Mare’s tails
5.6\u2002Woven mesh pulling grips and basket grips <\/td>\n<\/tr>\n
53<\/td>\n5.7\u2002Tension limiting devices <\/td>\n<\/tr>\n
55<\/td>\n5.8\u2002Lubrication <\/td>\n<\/tr>\n
58<\/td>\n6.\u2002Pulling activities
6.1\u2002Pre-pulling considerations <\/td>\n<\/tr>\n
59<\/td>\n6.2\u2002Set-up considerations
6.3\u2002Installation considerations <\/td>\n<\/tr>\n
60<\/td>\n6.4\u2002Pulling <\/td>\n<\/tr>\n
61<\/td>\n6.5\u2002Pullbacks <\/td>\n<\/tr>\n
62<\/td>\n6.6\u2002Pushbys <\/td>\n<\/tr>\n
63<\/td>\n6.7\u2002Pullbys <\/td>\n<\/tr>\n
65<\/td>\n6.8\u2002Pulling in the jam ratio <\/td>\n<\/tr>\n
67<\/td>\n6.9\u2002Staggered or gang pulls
6.10\u2002Overfill conditions
6.11\u2002Figure-eight cable configurations <\/td>\n<\/tr>\n
68<\/td>\n7.\u2002Conduit-cable pulling charts
7.1\u2002General and methodology
7.2\u2002Cable types and raceway configurations <\/td>\n<\/tr>\n
69<\/td>\n7.3\u2002Use of conduit-cable pulling charts <\/td>\n<\/tr>\n
70<\/td>\n7.4\u2002Pulling tensions and bend correction factors <\/td>\n<\/tr>\n
71<\/td>\n8.\u2002Post cable pulling activities
8.1\u2002Post installation considerations <\/td>\n<\/tr>\n
72<\/td>\n8.2\u2002Securing cable to raceway <\/td>\n<\/tr>\n
78<\/td>\n8.3\u2002Support and restraint devices <\/td>\n<\/tr>\n
80<\/td>\n9.\u2002Cable testing
9.1\u2002General <\/td>\n<\/tr>\n
81<\/td>\n9.2\u2002Low voltage power, control, and instrumentation cables <\/td>\n<\/tr>\n
82<\/td>\n9.3\u2002Medium voltage power cables <\/td>\n<\/tr>\n
83<\/td>\n9.4\u2002Additional diagnostic testing <\/td>\n<\/tr>\n
84<\/td>\nAnnex\u00a0A (normative) Conduit-cable pulling charts <\/td>\n<\/tr>\n
96<\/td>\nAnnex B (informative) Use of conduit-cable pulling chart examples
B.1\u2002Example #1 <\/td>\n<\/tr>\n
97<\/td>\nB.2\u2002Example #2 <\/td>\n<\/tr>\n
99<\/td>\nB.3\u2002Example #3 <\/td>\n<\/tr>\n
101<\/td>\nAnnex C (informative) Conduit-cable pulling chart methodology
C.1\u2002Pull tension calculation <\/td>\n<\/tr>\n
102<\/td>\nC.2\u2002Maximum allowable tension <\/td>\n<\/tr>\n
103<\/td>\nC.3\u2002Lcond, Lswbp <\/td>\n<\/tr>\n
104<\/td>\nC.4\u2002Maximum effective conduit length <\/td>\n<\/tr>\n
105<\/td>\nAnnex D (informative) Conduit-cable pulling chart bend correction factor <\/td>\n<\/tr>\n
107<\/td>\nAnnex E (informative) Glossary <\/td>\n<\/tr>\n
110<\/td>\nAnnex F (informative) Example of a cable pulling calculation <\/td>\n<\/tr>\n
119<\/td>\nAnnex G (informative) Example of electrodynamic force calculation
G.1\u2002Description and input data
G.2\u2002Formula (Lorentz force calculation), same as Equation\u00a0(29) <\/td>\n<\/tr>\n
120<\/td>\nG.3\u2002Example calculations (at initiation of fault)
G.4\u2002Discussion of results <\/td>\n<\/tr>\n
121<\/td>\nAnnex H (informative) Bibliography <\/td>\n<\/tr>\n
127<\/td>\nBack cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IEEE Recommended Practice for Cable Installation in Generating Stations and Industrial Facilities<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2020<\/td>\n127<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":245844,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-245842","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/245842","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/245844"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=245842"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=245842"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=245842"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}