{"id":273720,"date":"2024-10-19T18:23:31","date_gmt":"2024-10-19T18:23:31","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-14511-32018-tc\/"},"modified":"2024-10-25T14:45:08","modified_gmt":"2024-10-25T14:45:08","slug":"bs-en-14511-32018-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-14511-32018-tc\/","title":{"rendered":"BS EN 14511-3:2018 – TC"},"content":{"rendered":"
1.1 Es gilt der Anwendungsbereich von EN 14511-1. 1.2 Diese Europ\u00e4ische Norm legt die Pr\u00fcfverfahren f\u00fcr die Bemessung und Leistung von Luftkondi-tionierern, Fl\u00fcssigkeitsk\u00fchls\u00e4tzen und W\u00e4rmepumpen, die Luft, Wasser oder Sole als W\u00e4rmetr\u00e4ger nutzen und mit elektrisch angetriebenen Verdichtern betrieben werden, f\u00fcr die Raumbeheizung und -k\u00fchlung fest. Diese Pr\u00fcfverfahren gelten auch f\u00fcr die Bemessung und Leistung von Prozess-K\u00fchlern. Sie legt weiterhin ein Verfahren zur Pr\u00fcfung und Angabe von W\u00e4rmer\u00fcckgewinnungsleistungen, systemreduzierten Leistungen sowie der Leistung von Einzelger\u00e4ten von Multi-Split-Systemen f\u00fcr die Aufstellung im Innenraum, soweit zutreffend, fest. Diese Europ\u00e4ische Norm bietet au\u00dferdem die M\u00f6glichkeit, die Leistung von Multi-Split-Systemen und modularen Multi-Split-Systemen mit W\u00e4rmer\u00fcckgewinnung durch getrennte Leistungsbemessung von Ger\u00e4ten f\u00fcr die Aufstellung im Innenraum und Ger\u00e4ten f\u00fcr die Au\u00dfenaufstellung (Innen- und Au\u00dfenger\u00e4te) zu bemessen.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | compares BS EN 14511-3:2018 <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | TRACKED CHANGES Text example 1 \u2014 indicates added text (in green) <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
99<\/td>\n | European foreword European foreword <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | European foreword <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions 4 Tests for determination of capacities 4.1 Basic principles, method of calculation for the determination of capacities 4.1.1 Heating capacity <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | 4.1.2 Cooling capacity <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | 4.1.3 Heat recovery capacity 4.1.4 Capacity correction <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | 4.1.5 Effective power input <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | 4.1.6 Units on a distribution network of pressured water 4.1.7 Units for use with remote condenser 4.2 Test apparatus 4.2.1 Arrangement of the test apparatus <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | 4.2.2 Installation and connection of the test object <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | 4.3 Uncertainties of measurement <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | 4.4 Test procedure 4.4.1 Settings <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | 4.4.2 Output measurement for water (brine)-to-water (brine) and water (brine)-to-air units <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | 4.4.3 Output measurement for cooling capacity of air-to-water (brine) and air-to-air units 4.4.4 Output measurement for heating capacity of air-to-air and air-to-water units <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | 4.5 Test results 4.5.1 Data to be recorded <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | 4.5.2 Cooling capacity and heat recovery capacity calculation 4.5.3 Heating capacity calculation <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | 4.5.4 Effective power input calculation 5 Electrical consumptions for single duct and double duct units 5.1 Determination of power consumption due to standby mode 5.2 Determination of power consumption in off-mode <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | 5.3 Electricity consumption 6 Air flow rate measurement of ducted units 7 Heat recovery test for air-cooled multisplit system 7.1 Test installation 7.1.1 General 7.1.2 Three-room calorimeter method 7.1.3 Three-room air-enthalpy method 7.1.4 Two-room air-enthalpy method <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | 7.2 Test procedure 7.3 Test results 8 Test report 8.1 General information 8.2 Additional information 8.3 Rating test results <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | Annex A (normative) Calorimeter test method <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | Annex B (normative) Indoor air enthalpy test method <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | Annex C (informative) Conformance criteria <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | Annex D (informative) Symbols used in annexes <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | Annex E (informative) Test at system reduced capacity <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | Annex F (informative) Individual unit tests <\/td>\n<\/tr>\n | ||||||
143<\/td>\n | Annex G (normative) Determination of the liquid pump efficiency <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | Annex H (informative) Rating of indoor and outdoor units of multisplit and modular heat recovery multisplit systems <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | Annex I (normative) Air flow rate measurement <\/td>\n<\/tr>\n | ||||||
149<\/td>\n | Annex ZA (informative) Relationship between this European Standard and the requirements of Commission regulation (EC) No 206\/2012 aimed to be covered <\/td>\n<\/tr>\n | ||||||
150<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Tracked Changes. Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and process chillers, with electrically driven compressors – Test methods<\/b><\/p>\n |