{"id":28279,"date":"2024-10-17T02:58:18","date_gmt":"2024-10-17T02:58:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nc-energyconservationcode-09-2009\/"},"modified":"2024-10-24T14:01:51","modified_gmt":"2024-10-24T14:01:51","slug":"nc-energyconservationcode-09-2009","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nc\/nc-energyconservationcode-09-2009\/","title":{"rendered":"NC EnergyConservationCode 09 2009"},"content":{"rendered":"
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | NORTH CAROLINA STATE BUILDING CODE: ENERGY CONSERVATION CODE 2009 <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | COPYRIGHT <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | NORTH CAROLINA STATE BUILDING CODE COUNCIL SEPTEMBER 8, 2008 <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | NORTH CAROLINA DEPARTMENT OF INSURANCE <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | PREFACE <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | ORDINANCE <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | TABLE OF CONTENTS <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | CHAPTER 1 ADMINISTRATION SECTION 101 SCOPE AND GENERAL REQUIREMENTS SECTION 102 MATERIALS, SYSTEMS AND EQUIPMENT <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | TABLE 102.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR TABLE 102.1.3(2) DEFAULT DOOR U-FACTORS TABLE 102.1.3(3) DEFAULT GLAZED FENESTRATION SHGC SECTION 103 ALTERNATE MATERIALS\u2014METHOD OF CONSTRUCTION, DESIGNOR INSULATING SYSTEMS SECTION 104 CONSTRUCTION DOCUMENTS <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | SECTION 105 INSPECTIONS SECTION 106 VALIDITY SECTION 107 REFERENCED STANDARDS <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 GENERAL DEFINITIONS <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | CHAPTER 3 CLIMATE ZONES SECTION 301 CLIMATE ZONES TABLE 301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS Deleted TABLE 301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS Deleted FIGURE 301 NORTH CAROLINAa SECTION 302 DESIGN CONDITIONS <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | FIGURE 301.1 CLIMATE ZONES <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | TABLE 301.1 CLIMATE ZONES BY COUNTY TABLE 301.2 WARM HUMID COUNTIES <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | CHAPTER 4 RESIDENTIAL ENERGY EFFICIENCY SECTION 401 GENERAL SECTION 402 BUILDING THERMAL ENVELOPE TABLE 402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | TABLE 402.1.3 EQUIVALENT U-FACTORSa <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | TABLE 402.2.4 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE) TABLE 402.2.8 WALL INSULATION ALLOWANCES FOR TERMITE TREATMENT AND INSPECTION GAPS <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | SECTION 403 SYSTEMS (Mandatory) <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | SECTION 404 SIMULATED PERFORMANCE ALTERNATIVE (Performance) <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | TABLE 404.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | TABLE 404.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS\u2014continued <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | TABLE 404.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS\u2014continued <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | TABLE 404.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | CHAPTER 5 COMMERCIAL ENERGY EFFICIENCY SECTION 501 GENERAL SECTION 502 BUILDING ENVELOPE REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | TABLE 502.2(1) BUILDING ENVELOPE REQUIREMENTS\u2014OPAQUE ASSEMBLIES <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | TABLE 502.2(2) METAL BUILDING ASSEMBLY DESCRIPTIONS EQUATION 5-1 <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | TABLE 502.3 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | SECTION 503 BUILDING MECHANICAL SYSTEMS <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | TABLE 503.2.3(1) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | TABLE 503.2.3(2) UNITARY AND APPLIED HEAT PUMPS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | TABLE 503.2.3(3) PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINAL HEAT PUMPS TABLE 503.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES\/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | TABLE 503.2.3(5) BOILERS, GAS- AND OIL-FIRED, MINIMUM EFFICIENCY REQUIREMENTS TABLE 503.2.3(6) CONDENSING UNITS, ELECTRICALLY OPERATED, MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
42<\/td>\n | TABLE 503.2.3(7) WATER CHILLING PACKAGES, MINIMUM EFFICIENCY REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | TABLE 503.2.3(8) COPs AND IPLVs FOR NONSTANDARD CENTRIFUGAL CHILLERS < 150 TONS <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | TABLE 503.2.3(9) COPs AND IPLVs FOR NONSTANDARD CENTRIFUGAL CHILLERS \u2265 150 TONS, \u2264 300 TONS <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | TABLE 503.2.3(10) COPs AND IPLVs FOR NONSTANDARD CENTRIFUGAL CHILLERS > 300 TONS <\/td>\n<\/tr>\n | ||||||
46<\/td>\n | TABLE 503.2.3(11) PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | EQUATION 5-2 <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | TABLE 503.2.8 MINIMUM PIPE INSULATIONa (thickness in inches) TABLE 503.3.1(1) ECONOMIZER REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | TABLE 503.3.1(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | SECTION 504 SERVICE WATER HEATING(Mandatory) SECTION 505 ELECTRICAL POWER AND LIGHTING SYSTEMS (Mandatory) <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | TABLE 504.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | TABLE 505.5.2 INTERIOR LIGHTING POWER ALLOWANCES <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | TABLE 505.6.2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | SECTION 506 TOTAL BUILDING PERFORMANCE <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | CHAPTER 6 REFERENCED STANDARDS AAMA AMCA ANSI ARI <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | ASHRAE ASME ASTM CSA CTI <\/td>\n<\/tr>\n | ||||||
61<\/td>\n | DOE HI ICC IESNA NFRC <\/td>\n<\/tr>\n | ||||||
62<\/td>\n | SMACNA UL WDMA <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | APPENDIX DETAIL 502.2.1.5(1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE DETAIL 502.2.1.5(2) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS DOWN TO 3 INCHES ABOVE INTERIOR GROUND SURFACE <\/td>\n<\/tr>\n | ||||||
65<\/td>\n | INDEX <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" North Carolina State Building Code: Energy Conservation Code<\/b><\/p>\n |