{"id":323285,"date":"2024-10-19T22:23:33","date_gmt":"2024-10-19T22:23:33","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iso-105-b022013\/"},"modified":"2024-10-25T20:57:09","modified_gmt":"2024-10-25T20:57:09","slug":"bs-en-iso-105-b022013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iso-105-b022013\/","title":{"rendered":"BS EN ISO 105-B02:2013"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
6<\/td>\nForeword <\/td>\n<\/tr>\n
7<\/td>\nSection sec_1
Section sec_2
Section sec_3
Section sec_4
1\tScope
2\tNormative references
3\tPrinciple
4\tTerms and definitions <\/td>\n<\/tr>\n
8<\/td>\nSection sec_5
Section sec_5.1
Section sec_5.1.1
5\tMaterials and apparatus
5.1\tReference materials <\/td>\n<\/tr>\n
9<\/td>\nSection sec_5.1.2
Table tab_1
Section sec_5.1.3
Section sec_5.1.4
Section sec_5.2
Section sec_5.2.1
Section sec_5.2.1.1
Section sec_5.2.1.2
5.2\tLaboratory exposure devices <\/td>\n<\/tr>\n
10<\/td>\nSection sec_5.2.1.3
Section sec_5.2.1.4
Section sec_5.2.1.4.1
Section sec_5.2.1.4.2
Section sec_5.2.1.5
Section sec_5.2.1.5.1
Section sec_5.2.1.5.2
Section sec_5.2.1.5.3
Section sec_5.2.1.6
Section sec_5.2.1.7
Section sec_5.2.1.8
Section sec_5.2.2 <\/td>\n<\/tr>\n
11<\/td>\nSection sec_5.2.3
Section sec_5.2.4
Section sec_5.2.5
Section sec_5.2.6
Section sec_5.2.7
Section sec_5.2.8
Section sec_5.2.9
Section sec_6
Section sec_6.1
Section sec_6.2
Section sec_6.3
Section sec_6.4
Section sec_6.5
Section sec_6.6
6\tPreparation of test specimens <\/td>\n<\/tr>\n
12<\/td>\nSection sec_7
Table tab_2
Section sec_8
Section sec_8.1
Section sec_8.1.1
Section sec_8.1.2
7\tExposure conditions
8\tProcedure
8.1\tApparatus set-up <\/td>\n<\/tr>\n
13<\/td>\nSection sec_8.1.3
Section sec_8.2
Section sec_8.2.1
Figure fig_1
Section sec_8.2.2
Section sec_8.2.3
Section sec_8.2.4
Section sec_8.2.5
Section sec_8.2.6
8.2\tAdjustment of the effective humidity (see Clause\u00a07 and Annex\u00a0E) <\/td>\n<\/tr>\n
14<\/td>\nSection sec_8.2.7
Section sec_8.3
Section sec_8.3.1
Section sec_8.3.2
Section sec_8.3.2.1
Section sec_8.3.2.2
Section sec_8.3.2.3
Section sec_8.3.2.4
Section sec_8.3.2.5
Section sec_8.3.2.6
8.3\tExposure methods <\/td>\n<\/tr>\n
15<\/td>\nSection sec_8.3.2.7
Section sec_8.3.2.8
Section sec_8.3.2.9
Table tab_a
Figure fig_2
Section sec_8.3.3 <\/td>\n<\/tr>\n
16<\/td>\nSection sec_8.3.3.1
Section sec_8.3.3.2
Section sec_8.3.3.3
Section sec_8.3.3.4
Section sec_8.3.3.5
Section sec_8.3.3.6
Section sec_8.3.3.7 <\/td>\n<\/tr>\n
17<\/td>\nTable tab_b
Figure fig_3
Section sec_8.3.4
Section sec_8.3.4.1
Section sec_8.3.4.2
Section sec_8.3.4.3 <\/td>\n<\/tr>\n
18<\/td>\nSection sec_8.3.4.4
Section sec_8.3.4.5
Table tab_c
Figure fig_4
Section sec_8.3.5
Section sec_8.3.5.1 <\/td>\n<\/tr>\n
19<\/td>\nSection sec_8.3.5.2
Section sec_8.3.5.3
Section sec_8.3.5.4
Section sec_8.3.5.5
Section sec_8.3.6
Section sec_8.3.6.1
Section sec_8.3.6.2 <\/td>\n<\/tr>\n
20<\/td>\nTable tab_d
Figure fig_5
Section sec_8.3.6.3
Section sec_8.3.6.4 <\/td>\n<\/tr>\n
21<\/td>\nTable tab_e
Figure fig_6
Section sec_9
Section sec_9.1
Section sec_9.2
9\tAssessment of colour fastness <\/td>\n<\/tr>\n
22<\/td>\nSection sec_9.3
Section sec_9.4
Section sec_9.5
Section sec_9.6
Section sec_9.7
Section sec_9.8
Section sec_9.9
Section sec_10
10\tTest report <\/td>\n<\/tr>\n
25<\/td>\nAnnex sec_A
Annex sec_A.1
Annex sec_A.2
Annex\u00a0A
\n(normative)<\/p>\n

Requirements for xenon arc exposure devices <\/td>\n<\/tr>\n

26<\/td>\nAnnex sec_A.3 <\/td>\n<\/tr>\n
27<\/td>\nAnnex sec_A.4 <\/td>\n<\/tr>\n
28<\/td>\nAnnex sec_B
Annex sec_B.1
Annex\u00a0B
\n(normative)<\/p>\n

Procedures for measuring the irradiance uniformity in the specimen exposure area (for apparatus manufacturers only) <\/td>\n<\/tr>\n

29<\/td>\nFigure fig_B.1
Annex sec_B.2
Figure fig_B.2
Annex sec_B.3 <\/td>\n<\/tr>\n
30<\/td>\nAnnex sec_C
Table tab_C.1
Annex\u00a0C
\n(informative)<\/p>\n

Light exposure equivalents for blue wool lightfastness references L2 to L9 <\/td>\n<\/tr>\n

31<\/td>\nAnnex sec_D
Annex sec_D.1
Annex sec_D.2
Annex sec_D.3
Annex sec_D.4
Annex\u00a0D
\n(informative)<\/p>\n

General Information on colour fastness to Light <\/td>\n<\/tr>\n

32<\/td>\nAnnex sec_D.5
Annex sec_D.6 <\/td>\n<\/tr>\n
33<\/td>\nAnnex sec_E
Annex sec_E.1
Annex sec_E.2
Annex sec_E.2.1
Annex sec_E.2.2
Annex sec_E.2.3
Annex\u00a0E
\n(informative)<\/p>\n

Guidelines for Conducting Testing <\/td>\n<\/tr>\n

34<\/td>\nAnnex sec_E.3
Annex sec_E.3.1
Annex sec_E.3.2
Annex sec_E.3.3
Annex sec_E.3.4
Annex sec_E.4
Annex sec_E.4.1
Annex sec_E.4.2
Annex sec_E.4.3 <\/td>\n<\/tr>\n
35<\/td>\nAnnex sec_E.4.4
Annex sec_E.4.5
Annex sec_E.4.6
Annex sec_E.4.7
Annex sec_E.4.8 <\/td>\n<\/tr>\n
36<\/td>\nAnnex sec_E.4.9
Annex sec_E.5
Annex sec_E.5.1
Annex sec_E.5.2
Annex sec_E.5.3 <\/td>\n<\/tr>\n
37<\/td>\nTable tab_g
Figure fig_E.1
Annex sec_E.6
Annex sec_E.6.1
Annex sec_E.6.2
Annex sec_E.6.3 <\/td>\n<\/tr>\n
38<\/td>\nAnnex sec_E.6.4
Annex sec_E.6.5 <\/td>\n<\/tr>\n
39<\/td>\nAnnex sec_E.7
Annex sec_E.7.1
Annex sec_E.7.2
Annex sec_E.8
Annex sec_E.8.1
Annex sec_E.8.2 <\/td>\n<\/tr>\n
40<\/td>\nAnnex sec_E.8.3
Annex sec_E.8.4
Annex sec_E.8.5
Annex sec_E.8.6 <\/td>\n<\/tr>\n
41<\/td>\nReference ref_1
Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Textiles. Tests for colour fastness – Colour fastness to artificial light: Xenon arc fading lamp test<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2013<\/td>\n44<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":323288,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[878,2641],"product_tag":[],"class_list":{"0":"post-323285","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-59-080-01","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/323285","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/323288"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=323285"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=323285"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=323285"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}