{"id":363277,"date":"2024-10-20T01:44:42","date_gmt":"2024-10-20T01:44:42","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asme-bpvc-iii-1-nd-2007\/"},"modified":"2024-10-26T02:44:29","modified_gmt":"2024-10-26T02:44:29","slug":"asme-bpvc-iii-1-nd-2007","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asme\/asme-bpvc-iii-1-nd-2007\/","title":{"rendered":"ASME BPVC III 1 ND 2007"},"content":{"rendered":"
None<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
4<\/td>\n | LIST OF BPVC SECTIONS <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | CONTENTS ARTICLE ND- 1000 FIGURES <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | ARTICLE ND- 2000 FIGURES ARTICLE ND- 2000 TABLES <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | ARTICLE ND- 3000 FIGURES <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | ARTICLE ND- 3000 TABLES <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | ARTICLE ND- 4000 FIGURES <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | ARTICLE ND- 4000 TABLES <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | ARTICLE ND- 7000 FIGURES <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | STATEMENTS OF POLICY <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | PERSONNEL <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | ORGANIZATION OF SECTION III 1 GENERAL 2 SUBSECTIONS 3 ARTICLES 4 SUBARTICLES 5 SUBSUBARTICLES 6 PARAGRAPHS 7 SUBPARAGRAPHS <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 8 SUBSUBPARAGRAPHS 9 REFERENCES <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | SUMMARY OF CHANGES <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | LIST OF CHANGES IN BC ORDER <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | ARTICLE ND- 1000 INTRODUCTION ND- 1100 SCOPE ND- 1130 BOUNDARIES OF JURISDICTION APPLICABLE TO THIS SUBSECTION ND- 1131 Boundary of Components <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | ND-1132.2-1 ATTACHMENTS IN THE COMPONENT SUPPORT LOAD PATH THAT DO NOT PERFORM A PRESSURE RETAINING FUNCTION <\/td>\n<\/tr>\n | ||||||
39<\/td>\n | ND-1132.2-2 ATTACHMENTS THAT DO NOT PERFORM A PRESSURE RETAINING FUNCTION AND ARE NOT IN THE COMPONENT SUPPORT LOAD PATH (NONSTRUCTURAL ATTACHMENTS) <\/td>\n<\/tr>\n | ||||||
40<\/td>\n | ND-1132.2-3 ATTACHMENTS THAT PERFORM A PRESSURE RETAINING FUNCTION <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | ARTICLE ND- 2000 MATERIAL ND- 2100 GENERAL REQUIREMENTS FOR MATERIAL ND- 2110 SCOPE OF PRINCIPAL TERMS EMPLOYED ND- 2120 PRESSURE RETAINING MATERIAL <\/td>\n<\/tr>\n | ||||||
43<\/td>\n | ND- 2130 CERTIFICATION OF MATERIAL ND- 2140 WELDING MATERIAL ND- 2150 MATERIAL IDENTIFICATION ND- 2160 DETERIORATION OF MATERIAL IN SERVICE ND- 2170 HEAT TREATMENT TO ENHANCE IMPACT PROPERTIES ND- 2180 PROCEDURES FOR HEAT TREATMENT OF MATERIAL <\/td>\n<\/tr>\n | ||||||
44<\/td>\n | ND- 2190 NONPRESSURE- RETAINING MATERIAL ND- 2200 MATERIAL TEST COUPONS AND SPECIMENS FOR FERRITIC STEEL MATERIAL ND- 2210 HEAT TREATMENT REQUIREMENTS ND- 2211 Test Coupon Heat Treatment for Ferritic Material2 <\/td>\n<\/tr>\n | ||||||
45<\/td>\n | ND- 2220 PROCEDURE FOR OBTAINING TEST COUPONS AND SPECIMENS FOR QUENCHED AND TEMPERED MATERIAL ND- 2221 General Requirements <\/td>\n<\/tr>\n | ||||||
47<\/td>\n | ND- 2300 FRACTURE TOUGHNESS REQUIREMENTS FOR MATERIAL ND- 2310 MATERIAL TO BE IMPACT TESTED ND- 2311 Material for Which Impact Testing Is Required <\/td>\n<\/tr>\n | ||||||
48<\/td>\n | ND- 2320 IMPACT TEST PROCEDURES ND- 2330 TEST REQUIREMENTS AND ACCEPTANCE STANDARDS ND-2311-1 EXEMPTIONS FROM IMPACT TESTING UNDER ND-2311(a)(8) <\/td>\n<\/tr>\n | ||||||
49<\/td>\n | ND- 2340 NUMBER OF IMPACT TESTS REQUIRED ND-2331(a)-1 REQUIRED Cv LATERAL EXPANSION VALUES FOR PRESSURE RETAINING MATERIAL (EXCEPT BOLTING) <\/td>\n<\/tr>\n | ||||||
50<\/td>\n | ND- 2350 RETESTS ND-2331(a)-2 REQUIRED Cv ENERGY VALUES FOR PRESSURE RETAINING MATERIAL (EXCEPT BOLTING) ND-2333-1 REQUIRED Cv VALUES FOR BOLTING MATERIAL <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | ND- 2360 CALIBRATION OF INSTRUMENTS AND EQUIPMENT ND- 2400 WELDING MATERIAL ND- 2410 GENERAL REQUIREMENTS ND- 2420 REQUIRED TESTS <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | ND- 2430 WELD METAL TESTS <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | ND-2432.1-1 SAMPLING OF WELDING MATERIALS FOR CHEMICAL ANALYSIS ND-2432.2-1 WELDING MATERIAL CHEMICAL ANALYSIS <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | ND- 2440 STORAGE AND HANDLING OF WELDING MATERIAL ND- 2500 EXAMINATION AND REPAIR OF PRESSURE RETAINING MATERIAL ND- 2510 PRESSURE RETAINING MATERIAL ND-2433.1-1 DELTA FERRITE CONTENT <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | ND- 2530 EXAMINATION AND REPAIR OF PLATE ND- 2540 EXAMINATION AND REPAIR OF FORGINGS AND BARS <\/td>\n<\/tr>\n | ||||||
58<\/td>\n | ND- 2550 EXAMINATION AND REPAIR OF SEAMLESS AND WELDED (WITHOUT FILLER METAL) TUBULAR PRODUCTS AND FITTINGS ND- 2560 EXAMINATION AND REPAIR OF TUBULAR PRODUCTS AND FITTINGS WELDED WITH FILLER METAL <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | ND- 2570 EXAMINATION AND REPAIR OF STATICALLY AND CENTRIFUGALLY CAST PRODUCTS <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | ND-2571-1 REQUIRED EXAMINATIONS <\/td>\n<\/tr>\n | ||||||
63<\/td>\n | ND-2575.2-1 TYPICAL PRESSURE RETAINING PARTS OF PUMPS AND VALVES <\/td>\n<\/tr>\n | ||||||
66<\/td>\n | ND- 2580 EXAMINATION OF BOLTS, STUDS, AND NUTS ND- 2600 MATERIAL ORGANIZATIONS’ QUALITY SYSTEM PROGRAMS ND- 2610 DOCUMENTATION AND MAINTENANCE OF QUALITY SYSTEM PROGRAMS ND- 2700 DIMENSIONAL STANDARDS <\/td>\n<\/tr>\n | ||||||
67<\/td>\n | ARTICLE ND- 3000 DESIGN ND- 3100 GENERAL DESIGN ND- 3110 LOADING CRITERIA <\/td>\n<\/tr>\n | ||||||
68<\/td>\n | ND- 3120 SPECIAL CONSIDERATIONS ND- 3130 GENERAL DESIGN RULES <\/td>\n<\/tr>\n | ||||||
70<\/td>\n | ND-3132-1 DIMENSIONAL STANDARDS <\/td>\n<\/tr>\n | ||||||
74<\/td>\n | ND-3133.4-1 LENGTH LOF SOME TYPICAL CONICAL SECTIONS <\/td>\n<\/tr>\n | ||||||
75<\/td>\n | ND- 3300 VESSEL DESIGN ND- 3310 GENERAL REQUIREMENTS ND- 3320 DESIGN CONSIDERATIONS <\/td>\n<\/tr>\n | ||||||
76<\/td>\n | ND-3133.7-1 CHART FOR DETERMINING WALL THICKNESS OF TUBES UNDER EXTERNAL PRESSURE <\/td>\n<\/tr>\n | ||||||
77<\/td>\n | ND-3321-1 STRESS LIMITS FOR DESIGN AND SERVICE LOADINGS <\/td>\n<\/tr>\n | ||||||
78<\/td>\n | ND-3321-2 CLASSIFICATION OF STRESS IN VESSELS FOR SOME TYPICAL CASES <\/td>\n<\/tr>\n | ||||||
80<\/td>\n | ND-3324.2-1 PRINCIPAL DIMENSIONS OF TYPICAL HEADS ND-3324.2-1 VALUES OF FACTOR K <\/td>\n<\/tr>\n | ||||||
83<\/td>\n | ND-3324.8(b)-1 VALUES OF FACTOR M <\/td>\n<\/tr>\n | ||||||
84<\/td>\n | ND-3324.11(a)(6)-1 LARGE HEAD OPENINGS, REVERSE CURVE, AND CONICAL SHELL REDUCER SECTIONS ND-3324.11(b)(2)-1 VALUES OF DELTA FOR JUNCTIONS AT THE LARGE CYLINDER FOR ALPHA LESS THAN OR EQUAL TO 30 deg ND-3324.11(b)(3)-1 VALUES OF DELTA FOR JUNCTIONS AT THE SMALL CYLINDER FOR ALPHA LESS THAN OR EQUAL TO 30 deg <\/td>\n<\/tr>\n | ||||||
86<\/td>\n | ND-3325-1 SOME ACCEPTABLE TYPES OF UNSTAYED FLAT HEADS AND COVERS <\/td>\n<\/tr>\n | ||||||
90<\/td>\n | ND-3326.1-1 SPHERICALLY DISHED COVERS WITH BOLTING FLANGES <\/td>\n<\/tr>\n | ||||||
92<\/td>\n | ND-3329.1(e)-1 ACCEPTABLE PROPORTIONS FOR ENDS OR THROUGH STAYS <\/td>\n<\/tr>\n | ||||||
93<\/td>\n | ND-3329.6(b)-1 EXAMPLE OF TUBE SPACING WITH PITCH OF HOLES EQUAL IN EVERY ROW ND-3329.6(b)-2 EXAMPLE OF TUBE SPACING WITH PITCH OF HOLES UNEQUAL IN EVERY SECOND ROW ND-3329.6(b)-3 EXAMPLE OF TUBE SPACING WITH PITCH OF HOLES VARYING <\/td>\n<\/tr>\n | ||||||
94<\/td>\n | ND- 3330 OPENINGS AND REINFORCEMENT ND-3329.6(d)-1 EXAMPLE OF TUBE SPACING WITH TUBE HOLES ON DIAGONAL LINES <\/td>\n<\/tr>\n | ||||||
95<\/td>\n | ND-3329.6(d)-2 DIAGRAM FOR DETERMINING THE EFFICIENCY OF LONGITUDINAL AND DIAGONAL LIGAMENTS BETWEEN OPENINGS IN CYLINDRICAL SHELLS <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | ND-3329.6(g)-1 DIAGRAM FOR DETERMINING EQUIVALENT LONGITUDINAL EFFICIENCY OF DIAGONAL LIGAMENTS <\/td>\n<\/tr>\n | ||||||
97<\/td>\n | ND-3332.2-1 CHART FOR DETERMINING VALUE OF F <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | ND-3332.2-1 VALUES OF SPHERICAL RADIUS FACTOR K1 <\/td>\n<\/tr>\n | ||||||
100<\/td>\n | ND-3335.1(b)-1 SOME REPRESENTATIVE CONFIGURATIONS DESCRIBING THE te REINFORCEMENT DIMENSION <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | ND-3335.2-1 ARRANGEMENT OF MULTIPLE OPENINGS ND-3335.3(b)-1 MINIMUM DEPTH FOR FLANGE OF FLUED OPENINGS <\/td>\n<\/tr>\n | ||||||
102<\/td>\n | ND- 3350 DESIGN OF WELDED CONSTRUCTION ND-3351-1 WELDED JOINT LOCATIONS TYPICAL OF CATEGORIES A, B, C, AND D <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | ND-3352-1 TYPICAL BUTT JOINTS <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | ND-3358.1(a)-1 HEADS ATTACHED TO SHELLS <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | ND- 3360 SPECIAL VESSEL REQUIREMENTS. <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | ND-3361.1-1 BUTT WELDING OF PLATES OF UNEQUAL THICKNESSES ND-3361.3(a)-1 MINIMUM NUMBER OF PIPE THREADS FOR CONNECTIONS <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | ND- 3400 PUMP DESIGN ND- 3410 GENERAL REQUIREMENTS FOR CENTRIFUGAL PUMPS <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | ND- 3420 DEFINITIONS ND-3423-1 TYPICAL SINGLE VOLUTE CASING ND-3423-2 TYPICAL DOUBLE VOLUTE CASING ND-3416-1 STRESS AND PRESSURE LIMITS FOR DESIGN AND SERVICE LOADINGS <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | ND- 3430 DESIGN REQUIREMENTS FOR CENTRIFUGAL PUMPS ND-3433.4-1 MINIMUM TANGENTIAL INLET AND OUTLET WALL THICKNESSES <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | ND- 3440 DESIGN OF SPECIFIC PUMP TYPES ND-3436(c)-1 EXTERNAL AND INTERNAL ATTACHMENTS ND-3441.1-1 TYPE A PUMP <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | ND-3441.1-2 TYPE A PUMP <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | ND-3441.1(a)-1 TYPE A PUMP ND-3441.2-1 TYPE B PUMP ND-3441.3-1 TYPE C PUMP <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | ND-3441.3-2 TYPE C PUMP <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | ND-3441.4(a)-1 TYPE D PUMP ND-3441.5-1 TYPE E PUMP ND-3441.6(a)-1 TYPE F PUMP ND-3441.7(a)-1 AXIALLY SPLIT CASING, VOLUTE PUMP, TYPE G <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | ND-3441.7(a)-2 AXIALLY SPLIT CASING, VOLUTE PUMP, TYPE G ND-3441.7(c)-1 AXIALLY SPLIT CASING, VOLUTE PUMP, TYPE G Section B – B Typical Highly Stressed Sections of Pump Case <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | ND-3441.7(c)(2)-1 TYPICAL SECTION OF TYPE G PUMP ND-3441.7(c)(2)-2 TYPICAL SECTION OF TYPE G PUMP ND-3441.7(c)(2)-3 TYPICAL LOADS ON TYPE G PUMP <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | ND-3441.8-1 LONGITUDINAL SECTION THROUGH TYPE H PUMP ND-3441.8-2 TRANSVERSE SECTION THROUGH TYPE H PUMP <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | ND-3441.9-1 TYPE K PUMP <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | ND-3441.9-2 TYPE K PUMP <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | ND-3441.10-1 TYPE L PUMP <\/td>\n<\/tr>\n | ||||||
131<\/td>\n | ND-3441.10-2 TYPE L PUMP BOWL <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | ND- 3450 DESIGN OF CLASS 3 RECIPROCATING PUMPS ND- 3500 VALVE DESIGN ND- 3510 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | ND-3451(a)-1 HORIZONTAL SINGLE-ACTING POWER PUMP LIQUID ENDS <\/td>\n<\/tr>\n | ||||||
135<\/td>\n | ND- 3520 LEVELS B, C, AND D SERVICE LIMITS ND-3521-1 LEVEL A, LEVEL B, LEVEL C, AND LEVEL D SERVICE LIMITS <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | ND-3521-1 TYPICAL SECTIONS OF VALVE BODIES <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | ND- 3530 GENERAL RULES ND- 3590 PRESSURE RELIEF VALVE DESIGN <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | ND-3591.1-1 TYPICAL PRESSURE RELIEF DEVICES <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | ND-3591.1-2 TYPICAL PRESSURE RELIEF DEVICES <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | ND-3592.2(b)-1 CLASS 3 PRESSURE RELIEF DEVICES: LEVEL B, C, AND D SERVICE LOADINGS <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | ND-3595.3-1 VALVE NOZZLE <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | ND- 3600 PIPING DESIGN ND- 3610 GENERAL REQUIREMENTS ND-3611.2(e)-1 STRESS RANGE REDUCTION FACTORS <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | ND- 3620 DESIGN CONSIDERATIONS ND-3613.4-1 WELD JOINT EFFICIENCY FACTOR <\/td>\n<\/tr>\n | ||||||
145<\/td>\n | ND- 3640 PRESSURE DESIGN OF PIPING PRODUCTS. <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | ND-3622-1 EXAMPLES OF REVERSING AND NONREVERSING DYNAMIC LOADS <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | ND-3641.1(a)-1 VALUES OF A <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | ND-3642.1(c)-1 MINIMUM THICKNESS FOR BENDING <\/td>\n<\/tr>\n | ||||||
149<\/td>\n | ND-3643.2(b)-1 TYPICAL WELDED BRANCH CONNECTIONS <\/td>\n<\/tr>\n | ||||||
151<\/td>\n | ND-3643.2(b)-2 TYPICAL RIGHT ANGLE BRANCH CONNECTIONS MADE USING A FILLET WELD OR A PARTIAL PENETRATION WELD <\/td>\n<\/tr>\n | ||||||
152<\/td>\n | ND-3643.3(c)(1)-1 REINFORCEMENT OF BRANCH CONNECTIONS <\/td>\n<\/tr>\n | ||||||
153<\/td>\n | ND-3643.3(c)(1)-2 SOME REPRESENTATIVE CONFIGURATIONS DESCRIBING THE te REINFORCEMENT DIMENSION <\/td>\n<\/tr>\n | ||||||
155<\/td>\n | ND-3643.4(a)-1 REINFORCED EXTRUDED OUTLETS <\/td>\n<\/tr>\n | ||||||
157<\/td>\n | ND-3647.2-1 TYPES OF PERMANENT BLANKS <\/td>\n<\/tr>\n | ||||||
161<\/td>\n | ND- 3650 ANALYSIS OF PIPING SYSTEMS <\/td>\n<\/tr>\n | ||||||
163<\/td>\n | ND-3653.3-1 REDUCING OR FULL OUTLET BRANCH CONNECTIONS, OR TEES <\/td>\n<\/tr>\n | ||||||
166<\/td>\n | ND- 3660 DESIGN OF WELDS ND- 3670 SPECIAL PIPING REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
169<\/td>\n | ND-3673.2(b)-1 STRESS INDICES, FLEXIBILITY, AND STRESS INTENSIFICATION FACTORS <\/td>\n<\/tr>\n | ||||||
174<\/td>\n | ND-3673.2(b)-2 BRANCH CONNECTION NOMENCLATURE <\/td>\n<\/tr>\n | ||||||
176<\/td>\n | ND- 3690 DIMENSIONAL REQUIREMENTS FOR PIPING PRODUCTS ND- 3700 ELECTRICAL AND MECHANICAL PENETRATION ASSEMBLIES ND- 3720 DESIGN RULES ND- 3800 DESIGN OF ATMOSPHERIC STORAGE TANKS ND- 3810 GENERAL REQUIREMENTS ND- 3820 DESIGN CONSIDERATIONS <\/td>\n<\/tr>\n | ||||||
177<\/td>\n | ND- 3830 BOTTOM DESIGN ND- 3840 SHELL DESIGN ND-3821.5-1 DESIGN AND SERVICE LIMITS <\/td>\n<\/tr>\n | ||||||
178<\/td>\n | ND- 3850 ROOF DESIGN <\/td>\n<\/tr>\n | ||||||
180<\/td>\n | ND-3852.7-1 ALLOWABLE TENSILE STRESSES FOR ROOF SUPPORTS <\/td>\n<\/tr>\n | ||||||
181<\/td>\n | ND-3852.7-2 ALLOWABLE AXIAL COMPRESSION STRESSES FOR ROOF SUPPORTS <\/td>\n<\/tr>\n | ||||||
183<\/td>\n | D-3852.7-3 ALLOWABLE BENDING STRESSES FOR ROOF SUPPORTS <\/td>\n<\/tr>\n | ||||||
185<\/td>\n | ND-3852.7-4 ALLOWABLE SHEAR STRESSES FOR ROOF SUPPORTS <\/td>\n<\/tr>\n | ||||||
186<\/td>\n | ND-3852.7-5 ALLOWABLE SHEAR AND TENSION STRESSES FOR BOLTS FOR ROOF SUPPORTS ND-3852.7-6 ALLOWABLE BEARING STRESSES FOR BOLTS FOR ROOF SUPPORTS <\/td>\n<\/tr>\n | ||||||
188<\/td>\n | ND-3861-1 ROOF MANHOLES ND-3861-1 ROOF MANHOLES <\/td>\n<\/tr>\n | ||||||
189<\/td>\n | ND- 3860 TANK CONNECTIONS AND APPURTENANCES ND-3862(a)-1 FLANGED ROOF NOZZLES ND-3862(a)-1 FLANGED ROOF NOZZLES <\/td>\n<\/tr>\n | ||||||
190<\/td>\n | ND-3862(a)-2 SCREWED OR SOCKET WELD ROOF NOZZLES ND-3862(a)-2 SCREWED OR SOCKET WELD ROOF NOZZLES ND-3863-1 WELDED BOTTOM OUTLET ELBOW <\/td>\n<\/tr>\n | ||||||
191<\/td>\n | ND- 3900 DESIGN OF 0 psi TO 15 psi ( 0 kPa TO 100 kPa) STORAGE TANKS ND- 3910 GENERAL REQUIREMENTS ND-3863-1 WELDED BOTTOM OUTLET ELBOW <\/td>\n<\/tr>\n | ||||||
192<\/td>\n | ND- 3920 DESIGN CONSIDERATIONS ND-3865-1 PLATFORMS AND WALKWAYS ND-3865-2 STAIRWAYS <\/td>\n<\/tr>\n | ||||||
193<\/td>\n | ND-3865-3 STAIRWAY RISE, RUN, AND ANGLE RELATIONSHIPS <\/td>\n<\/tr>\n | ||||||
194<\/td>\n | ND-3921.8-1 DESIGN AND SERVICE LIMITS FOR STEEL TANKS <\/td>\n<\/tr>\n | ||||||
195<\/td>\n | ND-3922.1-1 BIAXIAL STRESS CHART FOR COMBINED TENSION AND COMPRESSION, 30,000 psi TO 38,000 psi (205 MPa to 260 MPa) YIELD STRENGTH STEELS <\/td>\n<\/tr>\n | ||||||
196<\/td>\n | ND-3922.1-2 REDUCTION OF DESIGN STRESSES REQUIRED TO ALLOW FOR BIAXIAL STRESSES OF OPPOSITE SIGN <\/td>\n<\/tr>\n | ||||||
198<\/td>\n | ND-3923.1-1 MAXIMUM ALLOWABLE STRESS VALUES FOR STRUCTURAL MEMBERS <\/td>\n<\/tr>\n | ||||||
200<\/td>\n | ND- 3930 DESIGN PROCEDURE <\/td>\n<\/tr>\n | ||||||
202<\/td>\n | ND-3932.1-1 SOME TYPICAL FREE BODY DIAGRAMS FOR CERTAIN SHAPES OF TANKS <\/td>\n<\/tr>\n | ||||||
203<\/td>\n | ND-3932.2(d)-1 FACTORS FOR DETERMINING VALUES OF R1 AND R2 FOR 2:1 ELLIPSOIDAL ROOFS AND BOTTOMS <\/td>\n<\/tr>\n | ||||||
206<\/td>\n | ND-3933.4(a)-1 COMPRESSION RING REGION <\/td>\n<\/tr>\n | ||||||
208<\/td>\n | ND-3933.5(d)-1 PERMISSIBLE DETAILS OF COMPRESSION RING CONSTRUCTION <\/td>\n<\/tr>\n | ||||||
209<\/td>\n | ND-3933.5(h)-1 SOME VALUES FOR kBASED ON n, THETA <\/td>\n<\/tr>\n | ||||||
210<\/td>\n | ARTICLE ND- 4000 FABRICATION AND INSTALLATION ND- 4100 GENERAL REQUIREMENTS ND- 4110 INTRODUCTION ND- 4120 CERTIFICATION OF MATERIAL AND FABRICATION BY COMPONENT CERTIFICATE HOLDER <\/td>\n<\/tr>\n | ||||||
211<\/td>\n | ND- 4130 REPAIR OF MATERIAL ND- 4200 FORMING, FITTING, AND ALIGNING ND- 4210 CUTTING, FORMING, AND BENDING <\/td>\n<\/tr>\n | ||||||
212<\/td>\n | ND- 4220 FORMING TOLERANCES <\/td>\n<\/tr>\n | ||||||
213<\/td>\n | ND-4221.1-1 MAXIMUM DIFFERENCE IN CROSS-SECTIONAL DIAMETERS <\/td>\n<\/tr>\n | ||||||
214<\/td>\n | ND-4221.2(a)-1 MAXIMUM PERMISSIBLE DEVIATION eFROM A TRUE CIRCULAR FORM <\/td>\n<\/tr>\n | ||||||
215<\/td>\n | ND- 4230 FITTING AND ALIGNING ND-4221.2(a)-2 MAXIMUM ARC LENGTH FOR DETERMINING PLUS OR MINUS DEVIATION <\/td>\n<\/tr>\n | ||||||
216<\/td>\n | ND-4233-1 BUTT WELD ALIGNMENT AND MISMATCH TOLERANCES FOR UNEQUAL I.D. AND O.D. WHEN COMPONENTS ARE WELDED FROM ONE SIDE AND FAIRING IS NOT PERFORMED ND-4232(a)-1 MAXIMUM ALLOWABLE OFFSET IN FINAL WELDED JOINTS <\/td>\n<\/tr>\n | ||||||
217<\/td>\n | ND- 4240 REQUIREMENTS FOR WELD JOINTS IN COMPONENTS <\/td>\n<\/tr>\n | ||||||
218<\/td>\n | ND-4243-1 ATTACHMENT OF PRESSURE PARTS TO PLATES TO FORM A CORNER JOINT <\/td>\n<\/tr>\n | ||||||
220<\/td>\n | ND-4243.1-1 TYPICAL FLAT HEADS, AND SUPPORTED AND UNSUPPORTED TUBESHEETS WITH HUBS <\/td>\n<\/tr>\n | ||||||
221<\/td>\n | ND-4244(a)-1 NOZZLES, AND BRANCH AND PIPING CONNECTIONS JOINED BY FULL PENETRATION BUTT WELDS <\/td>\n<\/tr>\n | ||||||
222<\/td>\n | ND-4244(b)-1 NOZZLES, AND BRANCH AND PIPING CONNECTIONS JOINED BY FULL PENETRATION CORNER WELDS <\/td>\n<\/tr>\n | ||||||
223<\/td>\n | ND-4244(c)-1 DEPOSITED WELD METAL USED AS REINFORCEMENT OF OPENINGS FOR NOZZLES, AND BRANCH AND PIPING CONNECTIONS <\/td>\n<\/tr>\n | ||||||
225<\/td>\n | ND-4244(d)-1 SOME ACCEPTABLE TYPES OF WELDED NOZZLES, AND BRANCH AND PIPING CONNECTIONS <\/td>\n<\/tr>\n | ||||||
226<\/td>\n | ND-4244(e)-1 SOME ACCEPTABLE TYPES OF WELDED NOZZLES <\/td>\n<\/tr>\n | ||||||
227<\/td>\n | ND-4244(e)-2 SOME ACCEPTABLE TYPES OF SMALL FITTINGS <\/td>\n<\/tr>\n | ||||||
228<\/td>\n | ND-4244(f)-1 TUBE CONNECTIONS <\/td>\n<\/tr>\n | ||||||
229<\/td>\n | ND-4244(g)-1 SOME ACCEPTABLE TYPES OF WELDED NOZZLES, AND BRANCH AND PIPING CONNECTIONS <\/td>\n<\/tr>\n | ||||||
230<\/td>\n | ND-4245-1 ATTACHMENT WELDS <\/td>\n<\/tr>\n | ||||||
232<\/td>\n | ND-4246.1(a)-1 TYPICAL BOTTOM AND BOTTOM-TO-SHELL JOINTS <\/td>\n<\/tr>\n | ||||||
233<\/td>\n | ND-4246.3-1 TYPICAL ROOF AND ROOF-TO-SHELL JOINTS <\/td>\n<\/tr>\n | ||||||
234<\/td>\n | ND-4246.5-1 ROOF MANHOLES <\/td>\n<\/tr>\n | ||||||
235<\/td>\n | ND-4246.5-2 FLANGED ROOF NOZZLES ND-4246.5-3 SCREWED OR SOCKET WELD ROOF NOZZLES ND-4246.5-4 WELDED BOTTOM OUTLET ELBOW <\/td>\n<\/tr>\n | ||||||
236<\/td>\n | ND- 4250 WELDING END TRANSITIONS \u2014 MAXIMUM ENVELOPE ND- 4300 WELDING QUALIFICATIONS ND- 4310 GENERAL REQUIREMENTS ND-4247.6(d)-1 MINIMUM SIZE FOR FILLET WELDS <\/td>\n<\/tr>\n | ||||||
237<\/td>\n | ND-4250-1 WELDING END TRANSITIONS MAXIMUM ENVELOPE <\/td>\n<\/tr>\n | ||||||
238<\/td>\n | ND- 4320 WELDING QUALIFICATIONS, RECORDS, AND IDENTIFYING STAMPS ND- 4330 GENERAL REQUIREMENTS FOR WELDING PROCEDURE QUALIFICATION TESTS <\/td>\n<\/tr>\n | ||||||
241<\/td>\n | ND- 4350 SPECIAL QUALIFICATION REQUIREMENTS FOR TUBE- TO-TUBESHEET WELDS ND- 4400 RULES GOVERNING MAKING, EXAMINING, AND REPAIRING WELDS ND- 4410 PRECAUTIONS TO BE TAKEN BEFORE WELDING ND- 4420 RULES FOR MAKING WELDED JOINTS <\/td>\n<\/tr>\n | ||||||
242<\/td>\n | ND- 4430 WELDING OF ATTACHMENTS <\/td>\n<\/tr>\n | ||||||
243<\/td>\n | ND-4427-1 FILLET AND SOCKET WELD DETAILS AND DIMENSIONS <\/td>\n<\/tr>\n | ||||||
244<\/td>\n | ND-4433-1 TYPES OF ATTACHMENT WELDS <\/td>\n<\/tr>\n | ||||||
245<\/td>\n | ND- 4450 REPAIR OF WELD METAL DEFECTS ND-4437.2(b)-1 SOME ACCEPTABLE METHODS OF ATTACHING STIFFENING RINGS TO SHELLS OF CYLINDRICAL VESSELS SUBJECTED TO EXTERNAL PRESSURE <\/td>\n<\/tr>\n | ||||||
246<\/td>\n | ND- 4460 WELDED TEST PLATES ND- 4470 WELDED STAYED CONSTRUCTION ND- 4500 BRAZING ND- 4510 RULES FOR BRAZING <\/td>\n<\/tr>\n | ||||||
247<\/td>\n | ND- 4520 BRAZING QUALIFICATION REQUIREMENTS ND-4470-1 WELDED STAYED CONSTRUCTION <\/td>\n<\/tr>\n | ||||||
248<\/td>\n | ND-4511-1 BRAZED CONNECTIONS FOR APPURTENANCES AND PIPING, NPS 4 (DN 100) AND LESS <\/td>\n<\/tr>\n | ||||||
249<\/td>\n | ND- 4530 FITTING AND ALIGNING OF PARTS TO BE BRAZED ND- 4540 EXAMINATION OF BRAZED JOINTS ND- 4600 HEAT TREATMENT ND- 4610 WELDING PREHEAT REQUIREMENTS ND-4524-1 MAXIMUM DESIGN TEMPERATURES FOR BRAZING FILLER METAL, \u00b0F (\u00b0C) <\/td>\n<\/tr>\n | ||||||
250<\/td>\n | ND- 4620 POSTWELD HEAT TREATMENT <\/td>\n<\/tr>\n | ||||||
251<\/td>\n | ND-4622.1-1 MANDATORY REQUIREMENTS FOR POSTWELD HEAT TREATMENT OF WELDS <\/td>\n<\/tr>\n | ||||||
252<\/td>\n | ND-4622.4(c)-1 ALTERNATIVE HOLDING TEMPERATURES AND TIMES <\/td>\n<\/tr>\n | ||||||
253<\/td>\n | ND-4622.7(b)-1 EXEMPTIONS TO MANDATORY PWHT <\/td>\n<\/tr>\n | ||||||
255<\/td>\n | ND- 4630 HEAT TREATMENT OF WELDS OTHER THAN THE FINAL POSTWELD HEAT TREATMENT ND- 4650 HEAT TREATMENT AFTER BENDING OR FORMING FOR PIPE, PUMPS, AND VALVES <\/td>\n<\/tr>\n | ||||||
256<\/td>\n | ND- 4660 HEAT TREATMENT OF ELECTROSLAG WELDS ND- 4700 MECHANICAL JOINTS ND- 4710 BOLTING AND THREADING ND- 4720 BOLTING FLANGED JOINTS ND- 4730 ELECTRICAL AND MECHANICAL PENETRATION ASSEMBLIES ND- 4800 EXPANSION JOINTS ND- 4810 FABRICATION AND INSTALLATION RULES FOR BELLOWS EXPANSION JOINTS <\/td>\n<\/tr>\n | ||||||
257<\/td>\n | ND-4730-1 PENETRATION ASSEMBLY ND-4810(c)-1 PERMISSIBLE ATTACHMENT WELDS FOR BELLOWS <\/td>\n<\/tr>\n | ||||||
258<\/td>\n | ARTICLE ND- 5000 EXAMINATION ND- 5100 GENERAL REQUIREMENTS FOR EXAMINATION ND- 5110 PROCEDURES, QUALIFICATIONS, AND EVALUATION ND- 5120 TIME OF EXAMINATION OF WELDS AND WELD METAL CLADDING <\/td>\n<\/tr>\n | ||||||
259<\/td>\n | ND- 5200 EXAMINATION OF WELDS ND- 5210 CATEGORY A VESSEL WELDED JOINTS IN VESSELS AND SIMILAR WELDED JOINTS IN PIPING, PUMPS, AND VALVES ND- 5220 CATEGORY B VESSEL WELDED JOINTS AND CIRCUMFERENTIAL WELDED JOINTS IN PIPING, PUMPS, AND VALVES ARTICLE ND- 5000 TABLE ND-5211.2-1 THICKNESS ABOVE WHICH FULL RADIOGRAPHIC EXAMINATION OF BUTT WELDED JOINT IS MANDATORY <\/td>\n<\/tr>\n | ||||||
260<\/td>\n | ND- 5230 CATEGORY C VESSEL WELDED JOINTS AND SIMILAR WELDED JOINTS IN PIPING, PUMPS, AND VALVES ND- 5240 CATEGORY D VESSEL WELDED JOINTS AND SIMILAR JOINTS IN PIPING, PUMPS, AND VALVES ND- 5260 WELDED STAYED CONSTRUCTION <\/td>\n<\/tr>\n | ||||||
261<\/td>\n | ND- 5270 SPECIAL WELDS ND- 5280 WELDED JOINTS IN STORAGE TANKS <\/td>\n<\/tr>\n | ||||||
262<\/td>\n | ND- 5300 ACCEPTANCE STANDARDS ND- 5320 RADIOGRAPHIC ACCEPTANCE STANDARDS <\/td>\n<\/tr>\n | ||||||
263<\/td>\n | ND- 5330 ULTRASONIC ACCEPTANCE STANDARDS ND- 5340 MAGNETIC PARTICLE ACCEPTANCE STANDARDS <\/td>\n<\/tr>\n | ||||||
264<\/td>\n | ND- 5350 LIQUID PENETRANT ACCEPTANCE STANDARDS ND- 5360 VISUAL ACCEPTANCE STANDARDS FOR BRAZED JOINTS ND- 5380 GAS AND BUBBLE FORMATION TESTING ND- 5400 SPOT EXAMINATION OF WELDED JOINTS ND- 5410 GENERAL REQUIREMENTS ND- 5420 MINIMUM EXTENT OF SPOT RADIOGRAPHIC EXAMINATION <\/td>\n<\/tr>\n | ||||||
265<\/td>\n | ND- 5430 STANDARDS FOR SPOT RADIOGRAPHIC EXAMINATION ND- 5440 EVALUATION AND RETESTS ND- 5500 QUALIFICATIONS AND CERTIFICATION OF NONDESTRUCTIVE EXAMINATION PERSONNEL ND- 5510 GENERAL REQUIREMENTS ND- 5520 PERSONNEL QUALIFICATION, CERTIFICATION, AND VERIFICATION <\/td>\n<\/tr>\n | ||||||
266<\/td>\n | ND- 5530 RECORDS ND- 5700 EXAMINATION REQUIREMENTS FOR EXPANSION JOINTS ND- 5720 BELLOWS EXPANSION JOINTS <\/td>\n<\/tr>\n | ||||||
268<\/td>\n | ARTICLE ND- 6000 TESTING ND- 6100 GENERAL REQUIREMENTS ND- 6110 PRESSURE TESTING OF COMPONENTS, APPURTENANCES, AND SYSTEMS <\/td>\n<\/tr>\n | ||||||
269<\/td>\n | ND- 6120 PREPARATION FOR TESTING <\/td>\n<\/tr>\n | ||||||
270<\/td>\n | ND- 6200 HYDROSTATIC TESTS ND- 6210 HYDROSTATIC TEST PROCEDURE ND- 6220 HYDROSTATIC TEST PRESSURE REQUIREMENTS ND- 6230 BELLOWS EXPANSION JOINTS <\/td>\n<\/tr>\n | ||||||
271<\/td>\n | ND- 6240 PROVISION FOR EMBEDDED OR INACCESSIBLE WELDED JOINTS IN PIPING ND- 6300 PNEUMATIC TESTS ND- 6310 PNEUMATIC TESTING PROCEDURES ND- 6320 PNEUMATIC TEST PRESSURE REQUIREMENTS ND- 6330 BELLOWS EXPANSION JOINTS ND- 6400 PRESSURE TEST GAGES ND- 6410 REQUIREMENTS FOR PRESSURE TEST GAGES <\/td>\n<\/tr>\n | ||||||
272<\/td>\n | ND- 6500 ATMOSPHERIC AND 0 psig TO 15 psig ( 0 kPa TO 100 kPa) STORAGE TANKS ND- 6510 TESTING OF ATMOSPHERIC STORAGE TANKS ND- 6520 TESTING OF 0 psig TO 15 psig ( 0 kPa TO 100 kPa) STORAGE TANKS <\/td>\n<\/tr>\n | ||||||
273<\/td>\n | ND- 6530 TEST GAGES <\/td>\n<\/tr>\n | ||||||
274<\/td>\n | ND- 6600 SPECIAL TEST PRESSURE SITUATIONS ND- 6610 COMPONENTS DESIGNED FOR EXTERNAL PRESSURE ND- 6620 PRESSURE TESTING OF COMBINATION UNITS ND- 6900 PROOF TESTS TO ESTABLISH DESIGN PRESSURE ND- 6910 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n | ||||||
275<\/td>\n | ND- 6920 PROCEDURES <\/td>\n<\/tr>\n | ||||||
278<\/td>\n | ND- 6930 PROCEDURE FOR COMPONENTS HAVING CHAMBERS OF SPECIAL SHAPE SUBJECT TO COLLAPSE <\/td>\n<\/tr>\n | ||||||
279<\/td>\n | ARTICLE ND- 7000 OVERPRESSURE PROTECTION ND- 7100 GENERAL REQUIREMENTS ND- 7110 SCOPE ND- 7120 INTEGRATED OVERPRESSURE PROTECTION ND- 7130 VERIFICATION OF THE OPERATION OF RECLOSING PRESSURE RELIEF DEVICES ND- 7140 INSTALLATION <\/td>\n<\/tr>\n | ||||||
280<\/td>\n | ND- 7150 ACCEPTABLE PRESSURE RELIEF DEVICES <\/td>\n<\/tr>\n | ||||||
281<\/td>\n | ND- 7160 UNACCEPTABLE PRESSURE RELIEF DEVICES ND- 7170 PERMITTED USE OF PRESSURE RELIEF DEVICES ND- 7200 OVERPRESSURE PROTECTION REPORT ND- 7210 RESPONSIBILITY FOR REPORT ND- 7220 CONTENT OF REPORT <\/td>\n<\/tr>\n | ||||||
282<\/td>\n | ND- 7230 CERTIFICATION OF REPORT ND- 7240 REVIEW OF REPORT AFTER INSTALLATION ND- 7250 FILING OF REPORT ND- 7300 RELIEVING CAPACITY REQUIREMENTS ND- 7310 EXPECTED SYSTEM PRESSURE TRANSIENT CONDITIONS <\/td>\n<\/tr>\n | ||||||
283<\/td>\n | ND- 7320 UNEXPECTED SYSTEM EXCESS PRESSURE TRANSIENT CONDITIONS ND- 7330 SYSTEM FAULTED CONDITIONS ND- 7400 SET PRESSURES OF PRESSURE RELIEF DEVICES ND- 7410 SET PRESSURE LIMITATIONS FOR EXPECTED SYSTEM PRESSURE TRANSIENT CONDITIONS ND- 7420 SET PRESSURE LIMITATIONS FOR UNEXPECTED SYSTEM EXCESS PRESSURE TRANSIENT CONDITIONS ND- 7500 OPERATING AND DESIGN REQUIREMENTS FOR PRESSURE AND VACUUM RELIEF VALVES ND- 7510 SAFETY, SAFETY RELIEF, AND RELIEF VALVES <\/td>\n<\/tr>\n | ||||||
285<\/td>\n | ND- 7520 PILOT OPERATED PRESSURE RELIEF VALVES <\/td>\n<\/tr>\n | ||||||
286<\/td>\n | ND- 7530 POWER ACTUATED PRESSURE RELIEF VALVES ND- 7540 SAFETY AND SAFETY RELIEF VALVES WITH AUXILIARY ACTUATING DEVICES ND- 7550 VACUUM RELIEF VALVES <\/td>\n<\/tr>\n | ||||||
287<\/td>\n | ND- 7560 ALTERNATIVE TEST MEDIA ND- 7600 NONRECLOSING PRESSURE RELIEF DEVICES ND- 7610 RUPTURE DISK DEVICES <\/td>\n<\/tr>\n | ||||||
288<\/td>\n | ND- 7620 INSTALLATION REQUIREMENTS ND- 7700 CERTIFICATION ND- 7710 RESPONSIBILITY FOR CERTIFICATION OF PRESSURE AND VACUUM RELIEF VALVES <\/td>\n<\/tr>\n | ||||||
289<\/td>\n | ND- 7720 RESPONSIBILITY FOR CERTIFICATION OF NONRECLOSING PRESSURE RELIEF DEVICES ND- 7730 CAPACITY CERTIFICATION OF PRESSURE RELIEF VALVES \u2014 COMPRESSIBLE FLUIDS <\/td>\n<\/tr>\n | ||||||
292<\/td>\n | ND-7734.2(a)-1 VALUES OF FFOR NONCHOKING FLOW <\/td>\n<\/tr>\n | ||||||
293<\/td>\n | ND- 7740 CAPACITY CERTIFICATION OF PRESSURE RELIEF VALVES \u2014 INCOMPRESSIBLE FLUIDS <\/td>\n<\/tr>\n | ||||||
295<\/td>\n | ND- 7750 CAPACITY CERTIFICATION OF VACUUM RELIEF VALVES <\/td>\n<\/tr>\n | ||||||
297<\/td>\n | ND- 7760 CAPACITY DETERMINATION OF RUPTURE DISK DEVICES ND-7754.2(a)-1 VALUES OF FFOR NONCHOKING FLOW <\/td>\n<\/tr>\n | ||||||
299<\/td>\n | ND- 7800 MARKING, STAMPING, AND DATA REPORTS ND- 7810 PRESSURE AND VACUUM RELIEF VALVES <\/td>\n<\/tr>\n | ||||||
300<\/td>\n | ND- 7820 RUPTURE DISK DEVICES ND- 7830 PRESSURE RELIEF VALVE IN COMBINATION WITH RUPTURE DISK DEVICES ND- 7840 CERTIFICATE OF AUTHORIZATION TO USE CODE SYMBOL STAMP <\/td>\n<\/tr>\n | ||||||
301<\/td>\n | ARTICLE ND- 8000 NAMEPLATES, STAMPING, AND REPORTS ND- 8100 GENERAL REQUIREMENTS <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" ASME BPVC – III – 1 – ND -2007 BPVC Section III, Rules for Constructions of Nuclear Facility Components, Division 1, Subsection ND, Class 3 Components<\/b><\/p>\n |