{"id":399448,"date":"2024-10-20T04:42:52","date_gmt":"2024-10-20T04:42:52","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e154-9\/"},"modified":"2024-10-26T08:31:22","modified_gmt":"2024-10-26T08:31:22","slug":"astm-e154-9","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e154-9\/","title":{"rendered":"ASTM-E154"},"content":{"rendered":"<\/p>\n
1.1 These test methods cover the determination of the properties of flexible membranes to be used as vapor retarders in contact with earth under concrete slabs, against walls, or as ground cover in crawl spaces. The test methods are applicable primarily to plastic films and other flexible sheets. The materials are not intended to be subjected to sustained hydrostatic pressure. The procedures simulate conditions to which vapor retarders may be subjected prior to and during installation, and in service.<\/p>\n
1.2 The test methods included are:<\/p>\n
1.3 The values stated in SI units are to be regarded as standard. The inch-pound values given in parentheses are provided for information only and are not considered standard.<\/p>\n
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/span><\/p>\n E154-08a Standard Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs, on Walls, or as Ground Cover<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Terminology <\/td>\n<\/tr>\n\n 2<\/td>\n Significance and Use
Sampling
Test Specimen
Water-Vapor Transmission of Material as Received
Water-Vapor Transmission after Wetting and Drying and after Long-Time Soaking <\/td>\n<\/tr>\n\n 3<\/td>\n Tensile Strength
Resistance to Puncture <\/td>\n<\/tr>\n\n 4<\/td>\n Resistance to Plastic Flow and Elevated Temperature
Effect of Low Temperatures on Flexibility
FIG. 1 <\/td>\n<\/tr>\n\n 5<\/td>\n Resistance to Deterioration from Organisms and Substances in Contacting Soil <\/td>\n<\/tr>\n \n 6<\/td>\n Resistance to Deterioration from Petroleum Vehicles for Soil Poisons
Resistance to Deterioration from Exposure to Ultraviolet Light <\/td>\n<\/tr>\n\n 7<\/td>\n Resistance to Flame Spread
Report
Keywords <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2008<\/td>\n 7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":399459,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1258,2637],"product_tag":[],"class_list":{"0":"post-399448","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-100-30","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/399448","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/399459"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=399448"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=399448"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=399448"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}