{"id":425618,"date":"2024-10-20T06:57:49","date_gmt":"2024-10-20T06:57:49","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-17020-52023\/"},"modified":"2024-10-26T13:08:11","modified_gmt":"2024-10-26T13:08:11","slug":"bs-en-17020-52023","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-17020-52023\/","title":{"rendered":"BS EN 17020-5:2023"},"content":{"rendered":"
This document is applicable to single and double leaf, hinged and pivoted doorsets with timber-based leaves or timber framed glazed door leaves, covered by EN 15269-3 and \/ or EN 15269-20. This document prescribes the methodology for extending the application of test results obtained from durability of self-closing test(s) conducted in accordance with EN 1191 and or EN 12605:2000, as appropriate. Subject to the completion of the appropriate self-closing test(s), the extended application can cover all or some of the following examples: – door leaf; pass doors; – glazed doorsets including vision panels and framed glazed doorsets; – side, transom and\/or overpanels; – ventilation grilles and\/or louvres; – wall or ceiling fixed elements (door frame\/suspension system); – glazing for door leaf, side, transom and flush over panels; – items of building hardware; – decorative finishes; – intumescent, strips, smoke, draught or acoustic seals; – alternative supporting construction(s).<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4 Determination of the field of extended application <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 5 Extended application report 6 Classification report <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Annex A (normative)Construction parameter variations <\/td>\n<\/tr>\n | ||||||
71<\/td>\n | Annex B (normative)Arrangements for hinged and pivoted doorsets incorporating side and\/or flush over panels <\/td>\n<\/tr>\n | ||||||
79<\/td>\n | Annex C (normative)Construction parameter variations <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Extended application of test results on durability of self-closing for fire resistance and\/or smoke control doorsets and openable windows – Durability of self-closing of hinged and pivoted timber doorsets<\/b><\/p>\n |