{"id":65649,"date":"2024-10-17T12:49:48","date_gmt":"2024-10-17T12:49:48","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d5523-2010\/"},"modified":"2024-10-24T18:23:51","modified_gmt":"2024-10-24T18:23:51","slug":"astm-d5523-2010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d5523-2010\/","title":{"rendered":"ASTM-D5523 2010"},"content":{"rendered":"<\/p>\n
1.1 This test method measures the hydrolyzable chlorine content of monomeric, aromatic isocyanates used as polyurethane raw materials and expresses it as HCl acidity. The test method is applicable to toluene diisocyanate (TDI) and monomeric methylene di(phenylisocyanate), known as MDI. The main sources of hydrolyzable chlorine and, therefore, acidity in monomeric aromatic isocyanates are carbamyl chlorides, acid chlorides, and dissolved phosgene. All of these compounds react with alcohols and water to form hydrochloric acid.<\/p>\n
1.2 This test method applies only to monomeric isocyanates in which all of the acidity is derived from species that generate HCl on solvolysis.<\/p>\n
1.3 The values stated in SI units are to be regarded as the standard.<\/p>\n
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/span><\/p>\n Note<\/span> 1There is no known ISO equivalent to this standard.<\/p>\n D5523-10 Standard Test Method for Polyurethane Raw Materials Acidity by Argentometric Determination of Hydrolyzable Chlorine in Monomeric, Aromatic Isocyanates<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 1<\/td>\n Scope
Referenced Documents
Terminology
Summary of Test Method
Significance and Use
Interferences
Apparatus <\/td>\n<\/tr>\n\n 2<\/td>\n Reagents and Materials
Sampling
Test Conditions
Procedure
Calculation <\/td>\n<\/tr>\n\n 3<\/td>\n Precision and Bias
Keywords <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"\n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n ASTM<\/b><\/a><\/td>\n 2010<\/td>\n 3<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":65650,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1179,2637],"product_tag":[],"class_list":{"0":"post-65649","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-83-080-20","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/65649","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/65650"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=65649"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=65649"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=65649"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}