{"id":132685,"date":"2024-10-19T07:35:57","date_gmt":"2024-10-19T07:35:57","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/asce-standard-24-2014\/"},"modified":"2024-10-24T23:43:23","modified_gmt":"2024-10-24T23:43:23","slug":"asce-standard-24-2014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/asce\/asce-standard-24-2014\/","title":{"rendered":"ASCE Standard 24 2014"},"content":{"rendered":"

Prepared by the Flood Resistant Design and Construction Committee of the Codes and Standards Activities Division of the Structural Engineering Institute of ASCE Flood Resistant Design and Construction, ASCE\/SEI 24-14, provides minimum requirements for design and construction of structures located in flood hazard areas and subject to building code requirements. Identification of flood prone structures is based on flood hazard maps, studies, and other public information. This standard applies to new structures, including subsequent work, and to work classified as substantial improvement of existing structures that are not historic. Standard ASCE\/SEI 24-14 introduces a new concept, Flood Design Class, that bases requirements for a structure on the risk associated with unacceptable performance. The standard includes requirements for the following:
\n basic siting and design and construction requirements for structures in flood hazard areas; minimum elevations for the lowest floor, flood damage-resistant materials, and floodproofing measures, each tied to a structure\u00e2\u20ac\u2122s Flood Design Class; structures in high risk flood hazard areas subject to flooding associated with alluvial fans, flash floods, mudslides, erosion, high velocity flow, coastal wave action, or ice jams and debris; structures in coastal high hazard areas (V Zones) and Coastal A Zones; flood damage-resistant materials; dry floodproofing and wet floodproofing; attendant utilities and equipment, including electrical service, plumbing systems, mechanical\/HVAC systems, and elevators; building access; and miscellaneous construction, including decks and porches, concrete slabs, garages and carports, accessory storage structures, chimneys and fireplaces, pools, and tanks.<\/p>\n

A detailed commentary containing explanatory and supplementary information to assist users of the standard is included for each chapter. Standard ASCE\/SEI 24-14 updates and replaces the previous Standard, ASCE\/SEI 24-05. It provides essential guidance on design and construction to structural engineers, design professionals, code officials, floodplain managers, and building owners. The standard is adopted by reference in model building codes.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nCover <\/td>\n<\/tr>\n
4<\/td>\nASCE STANDARDS <\/td>\n<\/tr>\n
6<\/td>\nPREFACE <\/td>\n<\/tr>\n
8<\/td>\nACKNOWLEDGMENTS <\/td>\n<\/tr>\n
10<\/td>\nUNIT CONVERSIONS <\/td>\n<\/tr>\n
12<\/td>\nCONTENTS <\/td>\n<\/tr>\n
18<\/td>\n1.0 GENERAL
1.1 Scope
1.2 Definitions <\/td>\n<\/tr>\n
22<\/td>\n1.3 Identification of flood hazard areas
1.4 Identification of flood-prone structures
1.4.1 General
1.4.2 Consideration for flood protective works <\/td>\n<\/tr>\n
23<\/td>\n1.4.3 Assignment of Flood Design Class to buildings and structures
1.5 Basic design and construction requirements
1.5.1 General
1.5.2 Elevation requirements
1.5.3 Foundation requirements
1.5.4 Use of fill
1.5.5 Anchorage and connections <\/td>\n<\/tr>\n
24<\/td>\n1.6 Loads in flood hazard areas
1.6.1 General
1.6.2 Combination of loads <\/td>\n<\/tr>\n
26<\/td>\n2.0 BASIC REQUIREMENTS FOR FLOOD HAZARD AREAS THAT ARE NOT IDENTIFIED AS COASTAL HIGH HAZARD AREAS AND COASTAL A ZONES
2.1 Scope
2.2 Development in floodways
2.3 Elevation requirements
2.4 Use of fill
2.4.1 Structural fill
2.5 Slabs-on-grade and footings
2.5.1 Use of slabs-on-grade
2.5.2 Footing design
2.6 Foundation walls <\/td>\n<\/tr>\n
27<\/td>\n2.7 Enclosures below the design flood elevation
2.7.1 Required openings in foundation walls and walls of enclosures
2.7.2 Design of openings
2.7.3 Installation of openings <\/td>\n<\/tr>\n
28<\/td>\n3.0 HIGH RISK FLOOD HAZARD AREAS
3.1 Scope
3.2 Alluvial fan areas
3.2.1 Protective works in active alluvial fan areas
3.3 Flash flood areas
3.3.1 Protective works in flash flood areas
3.4 Mudslide areas
3.4.1 Protective works in mudslide areas
3.5 Erosion-prone areas <\/td>\n<\/tr>\n
29<\/td>\n3.5.1 Protective works in erosion-prone areas
3.6 High velocity flow areas
3.6.1 Protective works in high velocity flow areas
3.7 Areas subject to wave action
3.7.1 Coastal High Hazard Areas and Coastal A Zones
3.7.2 Other high velocity wave action areas
3.8 Ice jam and debris areas
3.8.1 Protective works in ice jam and debris areas <\/td>\n<\/tr>\n
30<\/td>\n4.0 COASTAL HIGH HAZARD AREAS AND COASTAL A ZONES
4.1 Scope
4.1.1 Identification of Coastal High Hazard Areas and Coastal A Zones
4.2 General
4.3 Siting
4.4 Elevation requirements
4.5 Foundation requirements
4.5.1 General <\/td>\n<\/tr>\n
31<\/td>\n4.5.2 Special geotechnical considerations
4.5.3 Foundation depth
4.5.4 Use of fill
4.5.5 Deep foundations <\/td>\n<\/tr>\n
32<\/td>\n4.5.6 Pile design <\/td>\n<\/tr>\n
33<\/td>\n4.5.7 Posts, piers, and columns
4.5.8 Footings, mats, rafts, and concrete slabs that support columns or walls
4.5.9 Pile caps
4.5.10 Grade beams
4.5.11 Bracing
4.5.12 Shear walls
4.5.13 Stem walls <\/td>\n<\/tr>\n
34<\/td>\n4.6 Enclosed areas below design flood elevation
4.6.1 Breakaway walls
4.6.2 Openings in breakaway walls
4.7 Erosion control structures <\/td>\n<\/tr>\n
36<\/td>\n5.0 MATERIALS
5.1 General
5.2 Specificmaterials requirements for flood hazard areas
5.2.1 Metal connectors and fasteners
5.2.2 Structural steel
5.2.3 Concrete <\/td>\n<\/tr>\n
37<\/td>\n5.2.4 Masonry
5.2.5 Wood
5.2.6 Finishes <\/td>\n<\/tr>\n
38<\/td>\n6.0 DRY FLOODPROOFING AND WET FLOODPROOFING
6.1 Scope
6.2 Dry floodproofing
6.2.1 Dry floodproofing limitations
6.2.2 Dry floodproofing requirements
6.2.3 Limits on human intervention <\/td>\n<\/tr>\n
39<\/td>\n6.3 Wet floodproofing
6.3.1 Wet floodproofing limitations on use
6.3.2 Wet floodproofing requirements <\/td>\n<\/tr>\n
40<\/td>\n7.0 ATTENDANT UTILITIES AND EQUIPMENT
7.1 General
7.2 Electrical service
7.2.1 Service conduits and cables
7.2.2 Exposed conduits and cables
7.2.3 Electric meters
7.2.4 Panelboards, disconnect switches, and circuit breakers
7.2.5 Electric elements installed below minimum elevations <\/td>\n<\/tr>\n
41<\/td>\n7.3 Plumbing systems
7.3.1 Buried plumbing systems
7.3.2 Exposed plumbing systems
7.3.3 Plumbing systems installed below minimum elevations
7.3.4 Sanitary systems
7.4 Mechanical, heating, ventilation, and air conditioning systems
7.5 Elevators
7.5.1 Elevator shafts <\/td>\n<\/tr>\n
42<\/td>\n8.0 BUILDING ACCESS
8.1 General <\/td>\n<\/tr>\n
44<\/td>\n9.0 MISCELLANEOUS CONSTRUCTION
9.1 General
9.2 Decks and porches
9.2.1 Attached decks and porches
9.2.2 Detached decks and porches
9.3 Concrete slabs
9.4 Garages, carports, and accessory storage structures <\/td>\n<\/tr>\n
45<\/td>\n9.4.1 Attached garages, carports, and accessory storage structures
9.4.2 Detached garages, carports, and accessory storage structures
9.4.3 Multistory parking structures
9.5 Chimneys and fireplaces
9.6 Pools
9.6.1 Pools in Flood hazard areas other than Coastal High Hazard Areas and Coastal A Zones
9.6.2 Pools in Coastal High Hazard Areas, Coastal A Zones, and other high risk Flood hazard areas <\/td>\n<\/tr>\n
46<\/td>\n9.7 Tanks
9.7.1 Aboveground tanks
9.7.2 Underground tanks <\/td>\n<\/tr>\n
48<\/td>\n10.0 REFERENCES <\/td>\n<\/tr>\n
50<\/td>\nC1 GENERAL
C1.1 Scope <\/td>\n<\/tr>\n
51<\/td>\nC1.2 Definitions <\/td>\n<\/tr>\n
53<\/td>\nC1.3 Identification of flood hazard areas <\/td>\n<\/tr>\n
55<\/td>\nC1.4 Identification of flood-prone structures
C1.4.1 General <\/td>\n<\/tr>\n
56<\/td>\nC1.4.2 Consideration for flood protective works
C1.4.3 Assignment of Flood Design Class to buildings and structures <\/td>\n<\/tr>\n
57<\/td>\nC1.5 Basic design and construction requirements
C1.5.1 General
C1.5.2 Elevation requirements
C1.5.3 Foundation requirements <\/td>\n<\/tr>\n
58<\/td>\nC1.5.4 Use of fill
C1.5.5 Anchorage and connections
C1.6 Loads in Flood hazard areas
C1.6.1 General
C1.6.2 Combination of loads <\/td>\n<\/tr>\n
60<\/td>\nC2 BASIC REQUIREMENTS FOR FLOOD HAZARD AREAS THAT ARE NOT IDENTIFIED AS COASTAL HIGH HAZARD AREAS AND COASTAL A ZONES
C2.1 Scope
C2.2 Development in floodways
C2.3 Elevation requirements <\/td>\n<\/tr>\n
61<\/td>\nC2.4 Use of fill
C2.4.1 Structural fill
C2.5 Slabs-on-grade and footings
C2.5.1 Use of slabs-on-grade
C2.7 Enclosures below the design flood elevation <\/td>\n<\/tr>\n
62<\/td>\nC2.7.1 Required openings in foundation walls and walls of enclosures
C2.7.2 Design of openings <\/td>\n<\/tr>\n
63<\/td>\nC2.7.3 Installation of openings <\/td>\n<\/tr>\n
64<\/td>\nC3 HIGH RISK FLOOD HAZARD AREAS
C3.1 Scope
C3.2 Alluvial fan areas <\/td>\n<\/tr>\n
65<\/td>\nC3.2.1 Protective works in active alluvial fan areas
C3.3 Flash flood areas
C3.3.1 Protective works in flash flood areas
C3.4 Mudslide areas <\/td>\n<\/tr>\n
66<\/td>\nC3.5 Erosion-prone areas
C3.6 High velocity flow areas
C3.8 Ice jam and debris areas <\/td>\n<\/tr>\n
68<\/td>\nC4 COASTAL HIGH HAZARD AREAS AND COASTAL A ZONES
C4.1 Scope
C4.1.1 Identification of Coastal High Hazard Areas and Coastal A Zones <\/td>\n<\/tr>\n
69<\/td>\nC4.2 General <\/td>\n<\/tr>\n
70<\/td>\nC4.3 Siting
C4.4 Elevation requirements
C4.5 Foundation requirements
C4.5.1 General <\/td>\n<\/tr>\n
71<\/td>\nC4.5.3 Foundation depth
C4.5.4 Use of fill
C4.5.5 Deep foundations <\/td>\n<\/tr>\n
72<\/td>\nC4.5.6 Pile design
C4.5.7 Posts, piers, and columns <\/td>\n<\/tr>\n
73<\/td>\nC4.5.8 Footings, mats, rafts, and concrete slabs that support columns or walls
C4.5.10 Grade beams
C4.5.11 Bracing
C4.5.12 Shear walls
C4.5.13 Stem walls
C4.6 Enclosed areas below design flood elevation
C4.6.1 Breakaway walls
C4.6.2 Openings in breakaway walls <\/td>\n<\/tr>\n
74<\/td>\nC4.7 Erosion control structures <\/td>\n<\/tr>\n
76<\/td>\nC5 MATERIALS
C5.1 General
C5.2.1 Metal connectors and fasteners
C5.2.2 Structural steel
C5.2.3 Concrete <\/td>\n<\/tr>\n
77<\/td>\nC5.2.4 Masonry
C5.2.5 Wood <\/td>\n<\/tr>\n
78<\/td>\nC6 DRY FLOODPROOFING AND WET FLOODPROOFING
C6.1 Scope
C6.2 Dry floodproofing <\/td>\n<\/tr>\n
79<\/td>\nC6.2.1 Dry floodproofing limitations
C6.2.2 Dry floodproofing requirements
C6.2.3 Limits on human intervention
C6.3 Wet floodproofing <\/td>\n<\/tr>\n
82<\/td>\nC7 ATTENDANT UTILITIES AND EQUIPMENT
C7.1 General
C7.2 Electrical service <\/td>\n<\/tr>\n
83<\/td>\nC7.2.5 Electric elements installed below minimum elerations
C7.3.3 Plumbing systems installed below minimum elevations
C7.3.4 Sanitary systems
C7.4 Mechanical, heating, ventilation, and air conditioning systems
C7.5 Elevators
C7.5.1 Elevator shafts <\/td>\n<\/tr>\n
84<\/td>\nC8 BUILDING ACCESS
C8.1 General <\/td>\n<\/tr>\n
86<\/td>\nC9 MISCELLANEOUS CONSTRUCTION
C9.2 Decks and porches
C9.2.1 Attached decks and porches
C9.2.2 Detached decks and porches
C9.3 Concrete slabs
C9.4 Garages, carports, and accessory storage structures
C9.4.1 Attached garages, carports, and accessory storage structures <\/td>\n<\/tr>\n
87<\/td>\nC9.5 Chimneys and fireplaces
C9.6 Pools
C9.7 Tanks <\/td>\n<\/tr>\n
88<\/td>\nC10 REFERENCES <\/td>\n<\/tr>\n
90<\/td>\nINDEX
A
B
C
D
E
F <\/td>\n<\/tr>\n
91<\/td>\nG
H
I
L
M
N
O
P
R
S <\/td>\n<\/tr>\n
92<\/td>\nT
V
W <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

ASCE Standard 24: Flood Resistant Design and Construction<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASCE<\/b><\/a><\/td>\n2014<\/td>\n92<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":132689,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2660],"product_tag":[],"class_list":{"0":"post-132685","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-asce","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/132685","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/132689"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=132685"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=132685"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=132685"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}