{"id":135108,"date":"2024-10-19T07:46:24","date_gmt":"2024-10-19T07:46:24","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ies-rp-20-2014\/"},"modified":"2024-10-24T23:55:59","modified_gmt":"2024-10-24T23:55:59","slug":"ies-rp-20-2014","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ies\/ies-rp-20-2014\/","title":{"rendered":"IES RP 20 2014"},"content":{"rendered":"

The primary purpose of this document is to provide recommendations for design of fixed lighting for parking facilities. This document deals entirely with lighting and does not give advice on construction. It provides recommended practices for designing new lighting systems for parking facilities and it is not intended to be applied to existing lighting systems until such systems are redesigned. However, this document does represent current good practice. These recommendations include interior and exterior lighting practices for the reasonably safe movement of vehicular and pedestrian traffic in parking facilities, the enhancing of personal safety and security and the deterring of vandalism and theft, while optimizing energy use and minimizing maintenance. Their application may vary from these recommendations based upon sound engineering judgment.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nCover <\/td>\n<\/tr>\n
3<\/td>\nCopyright <\/td>\n<\/tr>\n
4<\/td>\nIES Roadway Lighting Committee <\/td>\n<\/tr>\n
6<\/td>\nContents <\/td>\n<\/tr>\n
8<\/td>\nFOREWORD <\/td>\n<\/tr>\n
9<\/td>\n1.0 INTRODUCTION
2.0 PURPOSE AND SCOPE <\/td>\n<\/tr>\n
10<\/td>\n3.0 TYPES OF PARKING FACILITIES ANDORGANIZATION OF THE PRACTICE
3.1 Application (Part I)
3.2 Parking Lots (Part II)
3.3 Parking Garages (Part III)
3.4 Organization of the Practice
PART I GENERAL BACKGROUND FORALL PARKING FACILITIES
4.0 GENERAL BACKGROUND ANDCOMMON CHARACTERISTICS
4.1 Illuminance Metrics <\/td>\n<\/tr>\n
11<\/td>\n4.2 Detection and Visual Tasks <\/td>\n<\/tr>\n
12<\/td>\n4.3 Vertical Illuminance
4.4 High Vehicular Traffic Locations
4.5 Security Lighting
4.6 Luminance
4.7 Lighting Zones <\/td>\n<\/tr>\n
13<\/td>\n4.8 Eye Adaptation <\/td>\n<\/tr>\n
14<\/td>\n4.9 Age Factors
5.0 LIGHT SOURCES AND CHARACTERISTICS
5.1 Light Source Types
5.2 Rated Life <\/td>\n<\/tr>\n
16<\/td>\n5.3 Efficacies
5.4 Configuration of Light Sources
5.5 Manufacturer Information
5.6 Ambient Temperature Conditions <\/td>\n<\/tr>\n
17<\/td>\n5.7 Lighting Maintenance <\/td>\n<\/tr>\n
21<\/td>\n6.0 LIGHTING QUALITY
6.1 Color Rendition
6.2 Color Temperature <\/td>\n<\/tr>\n
22<\/td>\n6.3 Glare
6.4 Obtrusive Light <\/td>\n<\/tr>\n
23<\/td>\nPART II PARKING LOTS AND TOP (OPEN)PARKING DECKS OF GARAGES
7.0 ILLUMINANCE RECOMMENDATIONSFOR PARKING LOTS
7.1 Horizontal Illuminance <\/td>\n<\/tr>\n
24<\/td>\n7.2 Vertical Illuminance
8.0 LUMINAIRE EQUIPMENTFOR PARKING LOTS <\/td>\n<\/tr>\n
25<\/td>\n8.1 Luminaire Classification System <\/td>\n<\/tr>\n
26<\/td>\n8.2 Area Lighting Luminaires <\/td>\n<\/tr>\n
27<\/td>\n8.3 Energy Conservation
8.4 Lighting Controls <\/td>\n<\/tr>\n
29<\/td>\n9.0 MAINTENANCE OF PARKING LOT LIGHTING
9.1 General
9.2 Obstruction of Light by Trees <\/td>\n<\/tr>\n
30<\/td>\n10.0 PARKING LOT APPLICATIONS
10.1 Requirements
10.2 Location of Luminaires <\/td>\n<\/tr>\n
31<\/td>\n10.3 Vandalism <\/td>\n<\/tr>\n
32<\/td>\nPART III PARKING GARAGES
11.0 ILLUMINANCE RECOMMENDATIONS FORPARKING GARAGES
11.1 General <\/td>\n<\/tr>\n
34<\/td>\n11.2 Ramps and Entrances
11.3 Uniformity
11.4 Stairways <\/td>\n<\/tr>\n
35<\/td>\n11.5 Emergency Lighting
11.6 Special Lighting
11.7 Glare <\/td>\n<\/tr>\n
36<\/td>\n12.0 LIGHTING EQUIPMENT
12.1 General
12.2 Shielded Luminaires
12.3 Non-Shielded Luminaires
13.0 ENERGY CONSERVATION
13.1 Use of Daylight (Daylighting) <\/td>\n<\/tr>\n
37<\/td>\n13.2 Lighting Controls <\/td>\n<\/tr>\n
38<\/td>\n14.0 PARKING GARAGE APPLICATIONS
15.0 SPECIAL MAINTENANCE ISSUESFOR PARKING GARAGES <\/td>\n<\/tr>\n
39<\/td>\nREFERENCES <\/td>\n<\/tr>\n
41<\/td>\nANNEX A \u2014 TABULAR COMPARISONS OF COMMON LAMP TYPES <\/td>\n<\/tr>\n
42<\/td>\nANNEX B \u2014 GENERAL PROCEDURE FOR CALCULATING MAINTAINEDILLUMINANCE IN PARKING LOTS AND GARAGES
B1.0 Calculation Procedure for MaintainedIlluminance
B2.0 Objectives and Specifications
B3.0 Light Loss Factors (LLFs) <\/td>\n<\/tr>\n
44<\/td>\nB4.0 Total Light Loss Factor
B5.0 Calculations
B6.0 Determinations of Average Illuminance fora Parking Lot <\/td>\n<\/tr>\n
46<\/td>\nB7.0 Determination of the Illuminance at aSpecific Point <\/td>\n<\/tr>\n
47<\/td>\nB8.0 Uniformity Ratios <\/td>\n<\/tr>\n
48<\/td>\nB9.0 Vertical Illuminance <\/td>\n<\/tr>\n
50<\/td>\nANNEX C \u2014 VISIBILITY-BASED ANALYSIS OF PARKING FACILITY LIGHTING
C1.0 Introduction
C2.0 Visibility Parameters <\/td>\n<\/tr>\n
52<\/td>\nC3.0 Analysis <\/td>\n<\/tr>\n
55<\/td>\nANNEX D – SI (METRIC) CONVERSIONS <\/td>\n<\/tr>\n
56<\/td>\nANNEX E – INGRESS PROTECTION RATINGS
ANNEX F: LUMINAIRE DISTRIBUTION TYPES <\/td>\n<\/tr>\n
58<\/td>\nANNEX G \u2013 AGE AND VISION CONSIDERATIONS <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

IES RP-20-14: Lighting for Parking Facilities<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IES<\/b><\/a><\/td>\n2014<\/td>\n59<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":135114,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2665],"product_tag":[],"class_list":{"0":"post-135108","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ies","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/135108","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/135114"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=135108"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=135108"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=135108"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}