{"id":373256,"date":"2024-10-20T02:33:08","date_gmt":"2024-10-20T02:33:08","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-7273-42015a12021-bundle\/"},"modified":"2024-10-26T04:29:14","modified_gmt":"2024-10-26T04:29:14","slug":"bs-7273-42015a12021-bundle","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-7273-42015a12021-bundle\/","title":{"rendered":"BS 7273-4:2015+A1:2021 Bundle"},"content":{"rendered":"

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\n30422111-LINK <\/td>\n<\/tr>\n
5<\/td>\nForeword <\/td>\n<\/tr>\n
7<\/td>\nIntroduction <\/td>\n<\/tr>\n
9<\/td>\n1 Scope <\/td>\n<\/tr>\n
10<\/td>\nFigure 1 \u2014 Scope of BS 7273\u20114
2 Normative references <\/td>\n<\/tr>\n
11<\/td>\n3 Terms and definitions <\/td>\n<\/tr>\n
15<\/td>\n4 Categories of actuation <\/td>\n<\/tr>\n
16<\/td>\n4.1 Selection of category <\/td>\n<\/tr>\n
17<\/td>\n4.2 Description of categories <\/td>\n<\/tr>\n
18<\/td>\nTable 1 \u2014 Conditions under which the interface with door release mechanisms is fail\u2011safe <\/td>\n<\/tr>\n
19<\/td>\n5 Exchange of information and definition of responsibilities
6 Variations from the recommendations of this standard <\/td>\n<\/tr>\n
20<\/td>\n7 Methods of actuation <\/td>\n<\/tr>\n
23<\/td>\n8 Mechanisms for unlocking and release of doors
8.1 General
8.2 Electrically held open fire doors
8.3 Electronically secured doors <\/td>\n<\/tr>\n
24<\/td>\n8.4 Powered sliding doors
9 Interface design <\/td>\n<\/tr>\n
25<\/td>\n9.1 General
9.2 Electronically secured doors or powered sliding doors
9.3 Electrically held\u2011open fire doors <\/td>\n<\/tr>\n
26<\/td>\n10 Monitoring, integrity and reliability of actuation arrangements <\/td>\n<\/tr>\n
27<\/td>\n11 Manual release controls
11.1 Manual release controls for self\u2011closing fire doors
11.2 Manual release controls for electronically secured doors and powered sliding doors <\/td>\n<\/tr>\n
29<\/td>\n12 Special considerations for the design of any associated fire detection and fire alarm system
12.1 All fire detection and fire alarm systems
12.2 Systems that actuate release mechanisms for electrically held\u2011open fire doors <\/td>\n<\/tr>\n
32<\/td>\nFigure 2 \u2014 Protection in corridors subdivided by electrically held open cross corridor fire doors <\/td>\n<\/tr>\n
33<\/td>\nFigure 3 \u2014 Protection where a fire door between a corridor and a stairway is electrically held open <\/td>\n<\/tr>\n
34<\/td>\nFigure 4 \u2014 Protection where a fire door between a room of limited size and a corridor or a stairway is electrically held\u2011open
12.3 Systems that actuate release mechanisms for electrically secured doors and powered sliding doors on means of escape <\/td>\n<\/tr>\n
35<\/td>\n13 Power supplies <\/td>\n<\/tr>\n
36<\/td>\n14 Cables, wiring and other interconnections
15 Acoustically\u2011actuated systems <\/td>\n<\/tr>\n
37<\/td>\n16 Radio\u2011actuated systems <\/td>\n<\/tr>\n
38<\/td>\n17 Electromagnetic compatibility <\/td>\n<\/tr>\n
39<\/td>\n18 Electrical safety
19 Door signage <\/td>\n<\/tr>\n
40<\/td>\n20 Commissioning <\/td>\n<\/tr>\n
42<\/td>\n21 Maintenance
21.1 Routine testing <\/td>\n<\/tr>\n
43<\/td>\n21.2 Inspection and servicing <\/td>\n<\/tr>\n
44<\/td>\n21.3 Recommendations for inspection and test over a 12 month period <\/td>\n<\/tr>\n
45<\/td>\nAnnex A (informative)\u2002 Applications for mechanisms for unlocking and releasing doors <\/td>\n<\/tr>\n
46<\/td>\nAnnex B (normative)\u2002 Selection of category of actuation <\/td>\n<\/tr>\n
47<\/td>\nTable B.1 \u2014 Selection of category of actuation for release of self\u2011closing fire doors <\/td>\n<\/tr>\n
48<\/td>\nTable B.2 \u2014 Selection of category of actuation for release of electronically locked doors on means of escape from buildings <\/td>\n<\/tr>\n
50<\/td>\nTable B.3 \u2014 Selection of category of actuation for release of powered sliding doors on means of escape
Annex C (informative)\u2002 Typical actuation arrangements for release mechanisms <\/td>\n<\/tr>\n
51<\/td>\nFigure C.1 \u2014 Use of relays at fire alarm CIE to actuate release mechanisms <\/td>\n<\/tr>\n
52<\/td>\nFigure C.2 \u2014 Use of addressable loop device to actuate release mechanisms <\/td>\n<\/tr>\n
53<\/td>\nFigure C.3 \u2014 Acoustic actuation of release mechanisms
Figure C.4 \u2014 Acoustic actuation of release mechanisms <\/td>\n<\/tr>\n
54<\/td>\nFigure C.5 \u2014 Combined acoustic and radio actuation of release mechanisms
Annex D (informative)\u2002 Example of a suitable sign for a manual release control <\/td>\n<\/tr>\n
55<\/td>\nFigure D.1 \u2014 Example of a suitable sign for a manual release control
Annex E (informative)\u2002 The advantages and disadvantages of acoustic actuation of release mechanisms <\/td>\n<\/tr>\n
56<\/td>\nAnnex F (informative)\u2002 The advantages and disadvantages of radio actuation of release mechanisms <\/td>\n<\/tr>\n
57<\/td>\nAnnex G (informative)\u2002 Model commissioning certificate <\/td>\n<\/tr>\n
58<\/td>\nFigure G.1 \u2014 Model commissioning certificate <\/td>\n<\/tr>\n
59<\/td>\nBibliography <\/td>\n<\/tr>\n
63<\/td>\n30432564-LINK <\/td>\n<\/tr>\n
67<\/td>\n1 Overview <\/td>\n<\/tr>\n
68<\/td>\n1.1 Reasons for change
2 Main commentary
2.1 Enhancements for people living with dementia <\/td>\n<\/tr>\n
69<\/td>\n2.2 Hold-open devices on self-closing flat entrance doors
2.3 Electronic locking on entrance doors to blocks of flats <\/td>\n<\/tr>\n
70<\/td>\n2.4 Routine testing
2.5 Use of relays on sounder circuits as an interface with door release mechanisms
2.6 Reference to BS 7273-6
Author
Technical reviewers <\/td>\n<\/tr>\n
71<\/td>\nDisclaimer <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Code of practice for the operation of fire protection measures – Actuation of release mechanisms for doors<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2021<\/td>\n72<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":373266,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[238,2641],"product_tag":[],"class_list":{"0":"post-373256","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-220-20","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/373256","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/373266"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=373256"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=373256"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=373256"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}