{"id":416164,"date":"2024-10-20T06:09:17","date_gmt":"2024-10-20T06:09:17","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-177632022\/"},"modified":"2024-10-26T11:25:59","modified_gmt":"2024-10-26T11:25:59","slug":"bs-en-177632022","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-177632022\/","title":{"rendered":"BS EN 17763:2022"},"content":{"rendered":"
This document specifies the procedure for the determination of the certified flow rate (CFR), a performance parameter for centrifuges, at specific fuel oil viscosities using a defined test oil and a defined test procedure. This document is applicable to marine fuel centrifuges. All values reported as CFR capacities are verified measured values on a defined CFR test bench. Separation efficiency is determined by a defined particle counting method. Scaling based on Stoke\u2019s law and disc stack design is excluded from this document.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | European foreword <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 4 Test arrangements 4.1 Test equipment <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | Figure 1 \u2014 Test rig 4.2 Test media 4.2.1 Test oil specification 4.2.2 Test oil kinematic viscosity <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4.2.3 Test oil density 4.2.4 Test oil dispersing additive 4.2.5 Test particle specification 5 Performance test 5.1 Oil viscosity 5.2 Particle concentration 5.3 Dispersing of particles into test medium <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 5.4 Test sequence 5.5 Test procedure 5.6 Sampling <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 5.7 Particle counting 6 Analysis 6.1 Calculation of separation efficiency 6.2 Calculation of the 85 % efficiency point <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Figure 2 \u2014 Example of separation efficiency\/flow rate 6.3 Correction of measured capacities Table 1 \u2014 Correction of measured capacities <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 6.4 Calculation of certified flow rate (CFR) 7 CFR results for similar machines (scaling) 8 Test report <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Annex A (informative) Dispersing the particles in the test medium <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Annex B (informative) Regeneration of test particle concentration Table B.1 \u2014 Calculation of the amount of particles to add <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Annex C (normative) Particle counting C.1 General Figure C.1 \u2014 Counting chamber according to Thoma (T) <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Figure C.2 \u2014 Counting chamber according to Thoma, \u201cnew\u201d (TN) <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Figure C.3 \u2014 Counting chamber according to Neubauer (N) <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Figure C.4 \u2014 Counting chamber according to Neubauer, \u201cimproved\u201d (NI) <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | Figure C.5 \u2014Illustration of glass ware with two (2) counting chambers C.2 Preparation of the Thoma\/ Neubauer counting chamber C.2.1 Cleaning C.2.2 Preparation for counting <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | Figure C.6 \u2014 Pushing on the cover glass with interference rings (Newton rings) C.3 Feeding the counting chamber <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | Figure C.7 \u2014 Feeding the counting chamber using a pipette C.4 Counting the particles within each counting field <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | Figure C.8 \u2014 Illustration of the meandering course <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Figure C.9 \u2014 Illustration of the counted particles (black ones) <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | C.5 Formulae Table C.1 \u2014 Symbols used for the formulae in this Annex <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | Annex D (informative) Example of correction of measured capacities Table D.1 \u2014 Example of a test to simulate 380 mm2\/s Table D.2 \u2014 Applied correction factors <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Centrifuges. Marine fuel centrifuges. Determination of particle separation performance and certified flow rate (CFR) under defined test conditions<\/b><\/p>\n |